21 Specifications

Environment
Storage Temperature
Operating Temperature
Humidity
Maximum Limits
Voltage between any two terminals
Power Supply
Network Power
Battery Power
Bus Power Voltage Measurement
Range
Calibrated Accuracy (DC)
Calibrated Accuracy (P-P)
Shield Voltage Measurement
Range
Calibrated Accuracy
CAN Voltage Measurement
Range
Calibrated Accuracy (signal)
Calibrated Accuracy (differential)
-40°C to 85°C
0°C to 40°C
5% to 90% (non-condensing)
±30 Vdc
90 mA @ 7 Vdc to 30Vdc
2 X AA Alkaline Batteries
2V to 26V & reverse polarity
0.5% ± 1 count
1.0% ± 2 counts
-10V to 1V
1.0% ± 2 counts
-5.25V to 9.98V
0.5% ± 20mV ± 2 counts
1.0% ± 20mV ± 4 counts