Specifications:

Rated Power
150 W / 300 W / 700 W
Battery Voltage
12 Vdc, 24 Vdc, or 48 Vdc
120 Vac / 60 Hz
AC Output Voltage (Vac) /
127 Vac / 50
Frequency
230 Vac / 50 Hz
Battery Current
Load Current

DIP Switch Settings:

DIP 1:
OPERATIONAL
CONTROL
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
DIP 1 ON =
DIP 1 ON =
DIP 1 OFF =
DIP 1 OFF =
Digital Control
Digital Control
Switch Control
Switch Control
DIP 2:
ALARM
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
SOUND
DIP 2 OFF = Alarm
DIP 2 OFF = Alarm
DIP 2 ON = Alarm
DIP 2 ON = Alarm
is Disabled
is Disabled
is Enabled
is Enabled
DIP 3 & DIP 7:
NOT USED
(DEFAULT IS
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
OFF)
DIP 4:
LOW VOLTAGE
DISCONNECT
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
(LVD)
DIP 4 ON = Presets
DIP 4 OFF = Custom
DIP 4 OFF = Custom

LED Indications:

AC Output LED
STATUS LED
Operation or State
No power or Battery
OFF
OFF
below 9.5 V
OFF
GREEN
AC Output OFF
GREEN
GREEN
AC Output ON
GREEN (BLINK)
GREEN
AC Standby Mode
Low Voltage Disconnect
RED (BLINK)
GREEN
(LVD) Warning
Low Voltage Disconnect
RED
GREEN
(LVD)
RED
RED
Inverter or System Fault*
OFF
RED
Inverter or System Fault*
Contact Information:
Contact Information:
Technical Support: morningstarcorp.com/support
Technical Support: morningstarcorp.com/support
Phone: 1-215-321-4457
Phone: 1-215-321-4457
4
© 2022 Morningstar Corporation. All Rights Reserved.
Communication
Remote Switch,
Options
Bluetooth, EIA-485, MS-CAN
AC Interface
Type-B Outlet or
Hz, or
Options
UNI Universal AC Outlet
Partial Specification List only. For the complete list
of specifications, see the SureSine Installation and
Operation s Manual.
DIP 5:
LOW VOLTAGE
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
DISCONNECT
(LVD) PRESETS
For 12 Vdc Systems:
DIP 5 OFF = 10.5 V
For 24 Vdc Systems:
DIP 5 OFF = 21.0 V
For 48 Vdc Systems:
DIP 5 OFF = 42.0 V
DIP 6:
STANDBY
MODE
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
DIP 6 OFF =
AC Output
Always ON
DIP 8:
BLUETOOTH
COMMUNICA-
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
TIONS
DIP 8 OFF =
Bluetooth Disabled
AC Output Mode Switch:
ON
OFF
(Front View)
(Front View)
Put the switch in
Press the |
a neutral position
I
I
O
O
(Side View)
(Side View)
II
II
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
DIP 5 ON = 11.5 V
IMPORTANT:
DIP 5 ON = 23.0 V
The SureSine Inverter is designed for
converting DC power to AC power only.
DIP 5 ON = 46.0 V
It will not charge batteries.
WARNING: Hazardous Voltage
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
The SureSine Inverter must be installed by a
DIP 6 ON =
qualified technician in accordance with the
AC Output
electrical regulations of the country of
OFF < 8 W
installation.
CAUTION: This guide must be used with the full product manual that includes important
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
information. Carefully read the SureSine Inverter product manual for all specifications,
DIP 8 ON =
safety, regulatory and warranty information, and for all required instructions on
Bluetooth Enabled
installation procedures, configuration, and operation.
REMOTE
Warranty Registration:
In the Box:
(Front View)
Press the | |
I
O
(Side View)
II
#10 Mounting Screws (x4)
MS-xxxxxx v0 (B02)
Quick Start Guide
Scan QR Code to go directly
to the SureSine Inverter
Installation Manual and
warranty information online.
https://www.morningstarcorp.com/product-registration/
Tools Required:
#2 Philips Screwdriver
3/16 (5 mm) & 1/8" (3.8 mm) Flathead
Screwdriver
Drill with a 1/8" (3.8 mm) bit
Multimeter
Crimping Tool
Wrench
SureSine Inverter
Terminal Resistor
SureSine Inverter Models:
150 W, 300 W & 700 W Models
(Factory-wired Versions ONLY)
For use with 12 Vdc, 24 Vdc,
or 48 Vdc Systems
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SureSine 150 W and is the answer not in the manual?

Questions and answers

Summary of Contents for Morningstar SureSine 150 W

  • Page 1 Inverter or System Fault* Inverter or System Fault* SureSine Inverter Contact Information: Contact Information: #10 Mounting Screws (x4) Technical Support: morningstarcorp.com/support Technical Support: morningstarcorp.com/support Terminal Resistor Phone: 1-215-321-4457 Phone: 1-215-321-4457 © 2022 Morningstar Corporation. All Rights Reserved. MS-xxxxxx v0 (B02)
  • Page 2 SureSine Inverter Quick Start Guide Minimum Clearance Requirements: Ensure circuit breakers are open, IMPORTANT: Example only. Actual wiring may vary. READ the SureSine WARNING: Risk of Fire STEP disconnect switches are open, and Installation and Operations Manual for mandatory safety requirements. AC Output All over-current protection devices fuses are removed from fuse holders.

This manual is also suitable for:

Suresine 300 wSuresine 700 w

Table of Contents