Installation
Electrical Connections
Electrical and grounding connections must comply with the applicable portions of the National Electrical
Code and/or other local codes.
Do not connect the appliance to the electrical supply until after the gas connection has been made.
When making electrical connections, use copper wire suitable for at least 200 °F (90 °C). The steamer must be grounded
in accordance with the National Electrical Code or applicable local codes.
The wiring diagram is located on the inside of the right panel.
Exhaust Hood
An exhaust system should be located directly above the boiler to exhaust steam and heat generated by the boiler.
Plumbing Connections (See Page 4)
Plumbing connections must comply with applicable sanitary, safety, and plumbing codes.
Water Supply Connection
The incoming cold water supply connection, at the rear of the boiler cabinet, requires 3/8" tubing and water pressure
of 25 - 50 psig. A manual shut-off valve must be provided convenient to the boiler; this valve should be open when
the boiler is in operation.
Drain Connection
The boiler drain (2" IPS) should be piped to a floor drain near the boiler. There should be no solid drain connection; an
"open gap" between the boiler and the floor drain is required.
10
PAGE
OF 20
Direct Steam Kettles Mounted on Electric Boiler Cabinet Base