Honeywell BW RigRat User Manual page 50

Local area gas monitor
Hide thumbs Also See for BW RigRat:
Table of Contents

Advertisement

AC Charging, Safe Area
For charging in safe areas, use the AC/DC adapter (P/N: W03-3044-000). Remove the dust cap
on the port labeled AC CHG SAFE AREA, align the indexing pins on the connectors, press in,
and then turn the ring until it clicks.
Make sure the cable connector is tight. Finger-tighten the connectors, but do not use tools.
It is strongly suggested to turn off the BW RigRat while charging on the AC charger. Running
the BW RigRat while charging results in a longer charging time.
Do not charge the BW RigRat with the AC charger in a hazardous area! Always charge the BW
RigRat with the AC charger in a safe area.
PIN 1
PIN 2
PIN 3
PIN 4
Intrinsically Safe Runtime Extension for Hazardous Areas
If the BW RigRat is to be charged or powered in a hazardous area, then an intrinsically safe (I.S.)
barrier box is necessary. Use P/N: W03-3018-000, and connect it to the IS CHG HAZARDOUS
port.
Note: The intrinsically safe line power is only providing runtime extension.
Requirements:
a.
W03-3018-000 I.S. barrier, 110~230VAC/50~60Hz IN, 23.5VDC/1.15W OUT
b.
W03-2168-000 I.S. barrier extension cable, 100 m, 3-pin plug
BW RigRat
IMPORTANT!
WARNING!
VDD
Charger port, positive, input, rated 5.7VDC/3A
Reserved HW Reset
CHG_STA Charging status indicate, output, In-charging/full-charged
GND
Charger port, negative
AC CHG SAFE AREA