The following instructions cover installation and wiring the BW RigRat I.S. Barrier. This equipment should
only be connected in accordance with applicable regulations by qualified personnel.
Step 1
Remove the four screws holding the cover
in place, and then lift off the cover.
Step 3
Pass wires through the glands on the exterior of the
case and then connect the wires to their terminals on
each connector,
DC OUT
Glands
AC IN
Step 5.1
Mounting on concrete or brick wall
before or after wiring.
Step 6
Secure the back cover by tightening the four
screws.
BW™ RigRat I.S. Barrier
Installation Guide
Pull out the input and output connectors.
Plug connectors back into the barrier. Then
secure the wires. And tighten the glands.
Step 5.2
Mounting on wooden wall before or
after wiring.
Download The BW RigRat User's Guide
The BW RigRat User's Guide should be
read and understood before installing
or using the BW RigRat I.S. Barrier. It is
available at: safety.honeywell.com
Step 2
Step 4
Step 5.3
Mounting on sheet or plate metal
(<30mm thick).
Rev. A
P/N: W03-4017-000

Advertisement

loading

Summary of Contents for Honeywell BW RigRat

  • Page 1 BW™ RigRat I.S. Barrier Installation Guide The following instructions cover installation and wiring the BW RigRat I.S. Barrier. This equipment should only be connected in accordance with applicable regulations by qualified personnel. Step 1 Step 2 Remove the four screws holding the cover Pull out the input and output connectors.
  • Page 2 BW™ RigRat I.S. Barrier Installation Guide Read and understand all the instructions in the BW RigRat User’s Guide before you start install. These equipment items may receive hazardous voltages on their terminals. If you do not follow the instructions correctly, you may expose yourself and others to serious injury as well as damage to equipment.