MG HE Series Manual page 54

Lithium-ion battery module
Table of Contents

Advertisement

Innovation in energy storage
Version 2.3 – 21-9-2022
5. Remove the nut, spring washer and washer from the negative battery pole.
6. Clean the battery pole and the cable lug's contact surfaces for a low resistance connection.
7. Connect the negative power cable with M8 cable lug to the M8 bolt as shown and place back
the washer, spring washer and nut. Tighten the nut with a torque of 20 Nm.
48