8.2.2 Explanation of menu level 1

SP1/rP1
Upper/lower limit value for system pressure, at which OUT1
switches with hysteresis setting.
Prerequisite: OUT1 setting is [Hno] or [Hnc]
FH1/FL1
Upper/lower limit value for system pressure, at which OUT1
switches with window setting.
Prerequisite: OUT1 setting is [Fno] or [Fnc]
EF
Extended functions / opening of menu level 2.
8.2.3 Explanation of menu level 2
rES
Restore factory setting.
ou1
Output function for OUT1:
Switching signal for the pressure limit values: hysteresis
function [H ..] or window function [F ..], either normally
open [. no] or normally closed [. nc].
ou2
Output function for OUT2:
Analog output for current system pressure: 4...20 mA [I] or
0...10 V [U]
dS1
Set delay for OUT1.
dr1
Reset delay for OUT1.
Standard unit of measurement (display):
uni
[bAr] / [PSI] / [MPA].
Lo
Minimum value memory for system pressure.
Hi
Maximum value memory for system pressure.
dAP
Damping of the switching point.
dAA
Damping of the analog output
Assignment of the display colors "red" and "green" within
coLr
the measuring range.