10.4

Repair

Bosch Rexroth offers a wide range of repair services. For further information,
please consult Bosch Rexroth Service, see
on page
10.5

Spare parts

Please contact Bosch Rexroth Service for clarification regarding spare parts,
see
safety instructions in these operating instructions when working with or on the
self-contained axis.
Table 11: Lifting gear / attachment devices
Designation
RING BOLT DIN580-M10-C15E
10.6

Exchange of components

To exchange defective components and in case of questions or doubt, please
contact the Bosch Rexroth service, see
on page
RE62290-B, 05.22
The self-contained axis has to be checked consistently for abnormalities or
changes. This relates to leakages, changed noise development, loose screw
fittings/connections, unusual heat development, damage to cables etc.
In order to avoid electrostatic charging, clean any dust accumulation using
a damp cloth
The extended visual inspection includes checking that the mounting ele-
ments and fittings are seated tightly. This has to be done with the system
switched off, depressurized and cooled down.
Improper repair!
WARNING
For repair, the self-contained axis may only be disas-
sembled to the extent described in these operating
instructions.
Defective parts may only be replaced by new, inter-
changeable, tested components in original equipment
quality.
Only use original spare parts from Bosch Rexroth for
repairing the self-contained axis.
The repair may only be carried out by authorized,
trained and instructed specialists.
Danger due to pressurized self-contained axis! Risk of
WARNING
injury! Severe injury when working at systems that have
not been stopped! Damage to property! Even once the
self-contained axis has been disconnected from the elec-
trical power supply, the system is still pressurized and is
permanently pre-stressed!
Observe the specifications of the system manufac-
turer and the system end-user!
Do not disconnect lines, connections or components
as long as the self-contained axis is under pressure.
The hydraulic circuit may only be opened by specifi-
cally trained personnel.
55.
⮫ Chapter 16.1 Service and support on page
Version
M10
55.
Self-contained axis
Exchange of components
⮫ Chapter 16.1 Service and support
55. In addition, observe the
Material number Data sheet /
standard
R900003438
DIN580
⮫ Chapter 16.1 Service and support
Bosch Rexroth AG
43 / 60