SERVICE MENU
In addition to a feature rich customer menu, the 3000
series also offers a service menu with the ability to fine
tune and monitor unit operation.
To initiate the Service menu hold both
seconds.
Actual Temps
Up
Down
The Actual Temp option in the service menu will display
raw thermistor readings without calculating offsets.
1. Press
to select "Actual Temps".
2. Press
.
3. Use
and
to scroll through available thermistor
readings.
To exit the Actual Temps menu press
to Menu" and press
to confirm.
All Errors
Up
Error ID
Down
and
for 5
Select
RETURN TO MENU
ACTUAL TEMPS
ZONE = 2°C
EVAP = °C
to select "Return
Number
Of Occurrences
Select
RETURN TO MENU
ALL ERRORS
NO COMM 0
ZONE T OPEN 0
The All Errors option keeps record of any system errors.
When an error occurs it is recorded to all errors. The
number next to the error indicates the number of recorded
instances. Errors in the log may not be currently active.
The error log memory is non volatile and is persistent
should power be lost and restored to the unit. See below
for a list of logged errors and their respective descriptions.
ID
Description
No Comm
Unit lost
communication
to the display.
Bin T Open
Bin thermistor
circuit open.
Condenser T
Evaporator
Open
thermistor
circuit open.
Bin T Short
Bin thermistor
circuit shorted.
Condenser T
Condenser
Short
thermistor
circuit shorted.
Temp Hi
Not used.
6H+
Temp Lo
Not used.
6H+
Temp Hi
Not used.
12H+
Temp Lo
Not used.
12H+
Time to
Water
Clean
circulation
system requires
cleaning.
Door Open
Door switch
5M
open for more
then 5 minutes.
Drain
Drain pump has
Blocked
detected a
problem.
WTD Reset
Software reset if
communication
is lost
u-line.com
Solution
Unplug the communication
cable from the user interface.
Check the black to red
conductors looking for 5 VDC. If
voltage is present replace the
user interface. If no voltage is
present check for 5 VDC at the
main board where the
communication cable plugs
onto the pins for the red and
black conductors. If 5 VDC is
not present replace the main
control board. If 5 VDC is
present replace the
communication cable.
Check thermistor connection to
harness for moisture or
corrosion. Also check
connection
where thermistor harness
attaches to main board. If
connections are valid replace
the thermistor.
Not used.
Not used.
Not used.
Not used.
Clean unit with 37050 cleaner.
Check door switch magnet reed
switch alignment when door is
in closed position. Check reed
switch connection at the
harness and the main board.
Check drain hose for restriction
or drain pump for correct
operation.
No Action Required
Control Operation - Service 2