3. Locate water
valve in the front
of the unit and
thread water
supply line
through.
NOTICE
Route the water
supply line
through the unit so it does not come into contact
with any internal components other than the
solenoid valve. Normal operation creates some
vibration. A water supply line contacting an
internal component or cabinet wall can cause
excessive noise during operation or damage to
the line.
4. On the back panel,
break away filler feature
in bushing with flat
screwdriver.
5. Thread water line
through back panel hole
(with bushing) and
connect to cold water
supply line.
6. Turn on water supply and check for leaks.
7. Reinstall back panel and grille/front access panel.
8. Install retaining clip.