  • Page 1 User Manual | - - Ver. 22 09 2022 KEYON SERIES SIH + SOH-09BIK SIH + SOH-18BIK SIH-07BIK SIH + SOH-09BIK2 SIH + SOH-24BIK SIH + SOH-12BIK SIH + SOH-12BIK2...
  • Page 2 „ O R I G I N A L I N S T R U C T I O N S “ I M P O R T A N T N O T E : Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this manual for future reference.
  • Page 3 For downloading manual for this pro- Pro stažení manuálu k tomuto pro- duct, please enter the model name at duktu zadejte modelové označení do this link: následujícího odkazu: Pre stiahnutie manuálu k tomuto pro- Um das Handbuch für dieses Produkt duktu zadajte modelové...
  • Page 4: Indoor Unit

    INDOOR UNIT Explanation of Symbols WARNING This symbol indicates the possibility of death or serious injury. This symbol indicates the possibility of injury or damage to CAUTION property. Indicates important but not hazard-related information, used NOTICE to indicate risk of property damage. Exception Clauses Manufacturer will bear no responsibilities when personal injury or property loss is caused by the following reasons.
  • Page 5 The refrigerant This appliance is not intended for use by persons Before install the Appliance filled (including children) with reduced physical, sensory appliance, read with flammable t i l i rience an d the installation gas R32. knowledge, unless they have been given superv- manual first.
  • Page 6 Safety operation of flammable refrigerant Installation notes Check whether there is fire source or potential fire source in the maintenance area. The air conditioner must be installed in a room - The naked flame is prohibited in the mainte- that is larger than the minimum room area. The nance area;...
  • Page 7: Safety Precautions

    Safety precautions WARNING Installation Installation or maintenance The grounding resistance must be performed by qua- should comply with nation- lified professionals. al electric safety regula- The appliance shall be in- tions. stalled in accordance with Air Conditioner should be national wiring regulations. properly grounded.
  • Page 8 Safety precautions CAUTION Installation Instructions for installation For the air conditioner with- and use of this product are out plug, a circuit breaker provided by the manufac- must be installed in the turer. line. Select a location which is The yellow-green wire in out of reach for children air conditioner is ground- and far away from animals...
  • Page 9: Operation And Maintenance

    Safety precautions WARNING Operation and Maintenance tioner to multi-purpose soc- This appliance can be used ket. Otherwise, it may cau- by children aged from 8 se fire hazard. years and above and per- Do disconnect power supp- sons with reduced physi- ly when cleaning air condi- cal, sensory or mental ca- tioner.
  • Page 10 Safety precautions CAUTION Operation and Maintenance frequently. Do not spill water on the re- Air conditioner gives off mote controller, otherwise burning smell. the remote controller may Indoor unit is leaking. be broken. Do not use fire or hair dry- er to dry the filter to avoid deformation or fire hazard.
  • Page 11: Parts Name

    Parts name Indoor Unit air inlet panel filter aux.button horizontal louver air outlet ■ If remote controller is lost or damaged, please use aux. button to turn on or turn off the air conditioner. The operation in details is as below: As shown in the figure, open panel and press aux.button to turn off the air conditioner.
  • Page 12: Buttons On Remote Controller

    Operation and introduction of remote controller Introduction for icons on display Buttons on remote controller screen I feel Set fan speed Turbo mode Send signal Auto mode Cool mode Dry mode Fan mode Heat mode Sleep mode 8℃ heating function Health mode Scavenging function X-FAN function...
  • Page 13: Introduction For Buttons On Remote Controller

    Introduction for buttons on After energization, Auto mode is defaulted. In Auto remote controller mode, the set temperature will not be displayed on NOTE the LCD, and the unit will automatically select the ● This is a general use remote controller. It could be suitable operation mode in accordance with the room used for the air conditioner with multifunction.
  • Page 14 NOTE I FEEL button ● Outdoor temperature display is not available for some Press this button to turn on I FEEL function. The models. At that time, indoor unit receives " " unit automatically adjust temperature according to signal, while it displays indoor set temperature. the sensed temperature.
  • Page 15: Replacement Of Batteries In Remote Controller

    WiFi button Replacement of batteries in remote controller Press "WiFi" button to turn on WiFi function, "WiFi" icon will be displayed on the remote controller; Hold "WiFi" button for 5s to turn off WiFi function reinstall battery and "WiFi" icon will disappear. Under off status, press "MODE"...
  • Page 17: Clean And Maintenance

    Clean and maintenance WARNING ■ The filter should be cleaned every three months . If there is much dust in the operation environme- WARNING nt, clean frequency can be increased. ■ Turn off the air conditioner and disconnect the ■ After removing the filter, do not touch fins to power before cleaning the air conditioner to av- avoid injury.
  • Page 18 Checked items before maintenance Phenomenon Solution Check items Whether there’s od- General phenomenon analysis Eliminate the odour Odours are our source, such as source. Clean the Please check below ite ms before asking for furniture and cigare- emitted filter. maintenance. If the malfunction still can’t be tte, etc.
  • Page 19: Outdoor Unit

    OUTDOOR UNIT Explanation of Symbols WARNING This symbol indicates the possibility of death or serious injury. This symbol indicates the possibility of injury or damage to CAUTION property. Indicates important but not hazard-related information, used NOTICE to indicate risk of property damage. Exception Clauses Manufacturer will bear no responsibilities when personal injury or property loss is caused by the following reasons.
  • Page 20 The refrigerant This appliance is not intended for use by persons Before install the Appliance filled (including children) with reduced physical, sensory appliance, read with flammable t i l i the installation gas R32. knowledge, unless they have been given superv- manual first.
  • Page 21 Safety operation of flammable refrigerant Installation notes Check whether there is fire source or potential fire source in the maintenance area. The air conditioner must be installed in a room - The naked flame is prohibited in the mainte- that is larger than the minimum room area. The nance area;...
  • Page 22: Installation Notice

    Parts name Outdoor Unit air inlet air outlet NOTE ● Actual product may be different from above graphics, please refer to actual product. Installation notice Space to the obstruction At least 50cm Drainage pipe NOTICE ● Please contact the local agent for installation. ●...
  • Page 23 Great Britain www.sinclair-world.com This product was manufactured in China (Made in China). R E P R E S E N T A T I V E SINCLAIR Global Group s.r.o. Purkynova 45 612 00 Brno Czech Republic T E C H N I C A L S U P P O R T SINCLAIR Global Group s.r.o.