PROBLEM
ON/OFF switch light ON
but timer does not light.
(Electronic Timer Models
only).
Steam flow does not stop
when timer stops.
Steam and/or water
draining around
compartment door.
See WARNING under
note #7.
Abnormal amount of
steam coming from drain.
Water leaking from the
bottom of cabinet.
Water leaking from water
pipes or drain lines.
Compartment bottom
dirty with food drippings.
Table 6-1 Trouble Shooting Guide (Continued)
POSSIBLE CAUSE
Timer transformer has failed.
Inoperative controls.
Operating in manual mode.
Heat Standby Switch has loosened or
failed closed.
(21CET16 only)
Heat standby timer is stuck closed.
(21CET8 or 24CEA10 only)
Inoperative controls inside cabinet.
It is common for a small amount of
water to condense around the door.
Water supply to condenser turned
OFF.
Hot water instead of cold water
connected to condenser fitting.
Compartment drain clogged or
covered.
External drain not properly installed,
should be free-air vented and pitched
down.
Door gasket or door parts worn.
Steamer not level.
Condenser inoperative
Hot water instead of cold water
connected to condenser fitting.
Water supply to condenser turned
OFF.
Condenser water line strainer and/or
nozzle are clogged.
Water supply line to the condenser
blocked, broken, or leaking.
Inoperative condenser solenoid.
Solid particles have partially blocked
the drain valve open.
Inoperative controls
Broken or loose plumbing inside
steamer cabinet.
Plumbing needs repair.
Juices and/or food leaking from pans
(Continued on next page)
See note #1.
See note #1.
Switch to timed mode for timer to be
effective.
See note #1.
See note #1.
Turn off electricity at main external power
switch. See note #1.
This is normal operation of the unit. No
action is necessary.
Open water supply valve.
Make proper connections. Refer to section
on water supply in installation manual. See
note #3.
Clean drain with USDA approved drain
cleaner. If condition persists see note #1
See note #2 and #3.
See note #1.
See note #2.
See note #1.
Make proper connections. Refer to section
on water supply in installation manual. See
note #3.
Open water supply valve.
Clean out condenser water supply strainer
and or condenser nozzle (see note 1).
Repair or replace water supply line.
See note #1.
See note #1.
Blowdown unit to rinse drain. If condition
persists see note #1.
See note #1.
Turn off electricity at main power switch
and close water supply valve(s). See note
#1.
See note #3.
Put a solid pan under perforated pans to
catch drippings, or put less food in pan.