Pulse duration
Pulse period
Weight (including batteries)
Storage temperature
Laser class in accordance with EN 60825-
1:2007
Protection class in accordance with IEC 60529 IP 65
5

Operation

5.1 Basic functions
Navigate to the desired function with the aid of the left or right arrow buttons.
▶ Always press the "Measure" button to select a function.
5.2 Inserting the batteries
2
Take care to ensure correct battery polarity. Change the batteries only
in pairs. Do not use damaged batteries.
▶ Open the battery compartment and insert the batteries.
5.3 Switching the laser range meter on and off
1. If the tool is switched off, press the on/off button or the "Measure" button
to switch it on.
2. If the tool is switched on, press the on/off button to switch it off.
5.4 Measuring using the spike
1. Fold out the spike through 90°. The spike can then be used as the
contact point.
Here, the spike helps to align the device while a stable position
is established. This is the case primarily for indirect, trapezoid
and Pythagoras measurements since these results are based on
estimated values.
Use the measuring extension PDA 72 for inaccessible places.
The device automatically detects the measuring extension.
confirmation window may appear in the display.
2. Fold out the spike through 180°. The measuring reference point is then
set automatically.
2068470
*2068470*
< 3.6 ns
8.3 ns ... 243 ns
165 g
(5.8 oz)
−30 ℃ ... 70 ℃
(−22 ℉ ... 158 ℉)
Laser class 2