Download Print this page

Limit Switch - GAPOSA XQ Sileo XS 40 Manual

Tubular motor
Hide thumbs Also See for XQ Sileo XS 40:

Advertisement

LIMIT SWITCH

AUTOMATIC LIMIT SETTING
Note: the roller shutter must be equipped
with stops (A) and automatic locks (B)
Press and hold the UP button for more than 2 seconds then
release. The motor runs upward to the TOP limit, stops itself
(because the bottom bar beats against the cassette) and sets
the TOP limit.
After few seconds it starts running automatically downwards to
self-set the BOTTOM limit.
1
When the Roller shutter is completely closed the motor stops
setting the BOTTOM limit
2"
To double check make a full
2
TOP/BOTTOM cycle of the roller
shutter
1/3
B
A
2"

Advertisement

loading

This manual is also suitable for:

Xq sileo xs 50Xq sileo xs 60Xq40Xq50Xq60Xs40 ... Show all