Good Faith Wall Surface/Tv Guidelines; Before Lighting Appliance - Majestic MARQ42IN Owner's Manual

Hide thumbs Also See for MARQ42IN:
Table of Contents

Advertisement

D. Good Faith Wall Surface/TV Guidelines
FIREPLACE OPENING
Figure 3.4. Good Faith Wall Surface Temperatures Above Appliance
NOTICE: Temperatures listed above are taken with a
temperature measuring probe as prescribed by the test
standard used for appliance certification. Temperatures
on walls or mantels taken with an infrared thermometer
may yield increased temperatures of up to 30 degrees or
more depending on the thermometer settings and material
characteristics being measured.
CEILING
150°F
160°F
52 IN. MIN.
155°F
46 IN.
160°F
40 IN.
34 IN.
165°F+
28 IN.
180°F+
22 IN.
230°F+
16 IN.
10 IN.
MEASUREMENTS FROM
TOP EDGE OF THE OPENING
APPLIANCE FRONT
Majestic • Owner's Manual MARQ36IN, MARQ42IN • 2270-981 Rev. J • 11/17
E. Before Lighting Appliance
Before operating this fireplace for the first time, have a
qualified service technician:
• Verify all shipping materials have been removed from
inside and/or underneath the firebox.
• Review proper placement of logs, ember material and/or
other decorative materials.
• Check the wiring.
• Check the air shutter adjustment.
• Ensure that there are no gas leaks.
• Ensure that the glass is sealed and in the proper position
and that the integral barrier is in place.
WARNING! Risk of Fire or Asphyxiation! DO NOT op-
erate fireplace with fixed glass assembly removed.