Table of Contents

Advertisement

INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
NOTICE: DO NOT discard this manual!
MARQUIS
SERIES
Models:
MARQ36IN, MARQ42IN
This appliance may be installed as an OEM
installation in manufactured home (USA
only) or mobile home and must be installed
in accordance with the manufacturer's
instructions and the Manufactured Home
Construction and Safety Standard, Title 24
CFR, Part 3280 in the United States, or the
Standard for Installation in Mobile Homes,
CAN/CSA Z240 MH Series, in Canada.
This appliance is only for use with the type(s)
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certified kit is used.
In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas fitter.
See Table of Contents for location of additional Commonwealth
of Massachusetts requirements.
Installation Manual
Installation and Appliance Setup
Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
• DO NOT store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Leave the building immediately.
- Immediately call your gas supplier from
a neighbor's phone. Follow the gas sup-
plier's instructions.
- If you cannot reach your gas supplier, call
the fire department.
• Installation and service must be performed
by a qualified installer, service agency, or the
gas supplier.
DANGER
DO NOT TOUCH GLASS
NEVER ALLOW CHILDREN
A barrier designed to reduce the risk of
burns from the hot viewing glass is provided
with this appliance and shall be installed for
the protection of children and other at-risk
individuals.
HOT GLASS WILL
CAUSE BURNS.
UNTIL COOLED.
TO TOUCH GLASS.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MARQ36IN and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Majestic MARQ36IN

  • Page 1 In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fitter. See Table of Contents for location of additional Commonwealth of Massachusetts requirements. Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 2: Table Of Contents

    B. Securing and Leveling the Appliance ....29 C. Installing Non-Combustible Facing Material ..30  = Contains updated information. Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 3: Installation Standard Work Checklist

    Comments: Further description of the issues, who is responsible (Installer/ Builder/ Other Trades, etc) and corrective action needed ____________________________________________________________________________________ Comments Communicated to party responsible ____________________ by ______________________on ___________ (Builder / Gen. Contractor/) (Installer) (Date)  = Contains updated information. 2270-982 9/16 Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 4: Product Specific And Important Safety Information

    47,500 23,500 (0-2000 FT) tected with ground-fault circuit-interrupter protection, in compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks. Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 5: Requirements For The Commonwealth Of Massachusetts

    VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB- of the installation. STRUCTIONS”. See Gas Connection section for additional Common- wealth of Massachusetts requirements. Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 6: Getting Started

    Safety glasses Level Reciprocating saw Flat blade screwdriver Non-corrosive leak check solution 1/2 - 3/4 in. length, #6 or #8 Self-drilling screws Caulking material (300 ºF minimum continuous exposure rating) Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 7: Framing And Clearances

    Location Inches Millimeters 1549 35-7/8 23-1/2 39-7/8 1013 59-1/4 1505 31-1/16 57-5/8 1464 29-5/8 35-3/16 3-7/8 34-3/16 2-3/4 54-15/16 1395 10-7/8 41-3/8 1051 16-1/8 Figure 3.1 Appliance Dimensions (MARQ36IN) Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 8 Millimeters 1702 41-7/8 1064 23-1/2 45-7/8 1165 65-5/16 1659 36-1/16 62-5/8 1591 32-11/16 40-3/16 1021 3-7/8 39-3/16 2-3/4 59-15/16 1522 10-7/8 46-3/8 1178 16-1/8 Figure 3.2 Appliance Dimensions (MARQ42IN) Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 9 (33 mm) MARQ42 FSMQ42 40-9/16 IN. (1030 mm) 41-13/16 IN. (1062 mm) 46-11/16 IN. (1186 mm) 3-9/16 IN. 1-1/4 IN. (91 mm) (32 mm) Figure 3.3 Decorative Front Dimensions Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 10: Clearances To Combustibles

    1/2 inch wall sheathing has not been installed. Inches 74-1/4 59-1/2 26-1/2 23-1/2 29-3/4 MARQ36IN Millimeters 1886 1511 2667 Inches 78-9/16 65-9/16 111-1/16 28-5/8 23-1/2 32-13/16 MARQ42IN Millimeters 1995 1665 2821  Figure 3.4 Appliance Locations Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 11 2 X 4 ONLY IN GRAY AREA NOTE: 2 X 4 HEADER CONFIGURATION 39 IN. 1 IN. FACTORY-SUPPLIED 1/2 IN. NON-COMBUSTIBLE BOARD = COMBUSTIBLES NOT ALLOWED Figure 3.5 Non-Combustible Zone Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 12: Constructing The Appliance Chase

    See Sec- tion 3.D. Inches 65-9/16 MARQ42IN Millimeters 1549 1665 1321 * Adjust framing dimensions for interior sheathing (such as sheetrock) Figure 3.6 Clearances to Combustibles (2 X 4 Construction) Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 13 ** 2 x 4 material must be framed down from 2 x 6 rough opening height B’ to rough opening height B. Figure 3.7 Clearances to Combustibles (2 x 6 Construction) Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 14: Hearth Extension

    WOOD OR OTHER COMBUSTIBLE FLOOR OR PLATFORM Figure 3.8 Non-Combustible Hearth Extension Dimensions Figure 3.10 Appliance Raised a Minimum of 3 Inches Above Combustible Surface. Non-Combustible Hearth Ex- tension NOT REQUIRED. Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 15: Termination Location And Vent Information

    Over 18/12 to 20/12 ..........7.5 Over 20/12 to 21/12 ..........8.0 * H minimum may vary depending on regional snowfall. Refer to local codes. Figure 4.1 Minimum Height From Roof To Lowest Discharge Opening Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 16: Chimney Diagram

    2 sides beneath the floor. venting system does not meet these requirements. • Vinyl protection kits are required for use with vinyl siding. Figure 4.3 Minimum Clearances for Termination Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 17: Approved Pipe

    1219 • Horizontal pipe installed level with no rise. DVP6A 3 to 6 76 to 152 2-1/8-4-1/4 54-108 DVP12A 3 to 12 76 to 305 2-1/8-8-1/2 54-216 Figure 4.4 Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 18: Vent Diagrams

    40 ft 12.2 m After V = 6 ft then H = 2 x V ft Maximum = 60 ft Maximum *when used with approved termination caps Figure 4.6 Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 19 16 ft 4.9 m 9 ft 2.7 m 18 ft 5.5 m 10 ft 3.0 m 20 ft 6.1 m = 60 ft Maximum = 20 ft Maximum Figure 4.7 Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 20 Shaded area of chart is for MARQ42IN (LP) must be adhered to. has no specific restrictions EXCEPT, = 2 x V and V cannot exceed 60 ft Maximum t max total total Figure 4.8 Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 21 = 2 ft. Min. (610 mm) Note: Flue restrictor is permit- ted ONLY on 30 ft. minimum vertical runs with no elbows. NOTE: Flue Restrictor ships in manual bag assembly. FLUE RESTRICTOR Figure 4.9 Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 22 Shaded area of chart is for MARQ42IN (LP) *No specific restrictions on this value EXCEPT = 50 ft (15.2 m) Max. After V = 6 ft, then H Max.= V Figure 4.10 Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 23 EXCEPT, after V = 6 ft, then H Max = 2 x V TOTAL = 50 ft (15.2 m) Max. TOTAL + TOTAL INSTALLED HORIZONTALLY Figure 4.11 Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 24: Pvlp-Slp And Pvi-Slp Information

    Figure 4.13 Baffle Adjustment - PVI-SLP Allowable Baffle Distance from PVLP-SLP to Appliance Minimum Maximum 2-15 ft. 1-1/2 in. 2-1/2 in. 16-39 ft. Closed 1-1/2 in. Greater than 40 Closed Table 4.2 Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 25: Vent Clearances And Framing

    (refer to Section 12.A.) attached to them. • See Section 7.E. for information for regarding the instal- lation of a horizontal termination cap. Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 26: Ceiling Firestop/Floor Penetration Framing

    INSTALL ATTIC INSULATION SHIELDS BEFORE OR AFTER INSTALLATION OF VENT SYSTEM CEILING FIRESTOP CEILING FIRESTOP INSTALLED BELOW CEILING INSTALLED ABOVE CEILING Figure 5.4 Installing the Attic Shield Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 27: Installing The Optional Heat-Zone ® Gas Kit

    • Determine the location for the air register/fan housing assembly. Reference the Heat-Zone Gas Kit instructions for the ® remaining installation steps. HEAT ZONE LOCATION ® LEFT AND RIGHT SIDES Figure 5.5 Heat Zone Cover Plate Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 28: Appliance Preparation

    3. Ensure gasket seal is in place prior to installing vent pipe sections. Gasket is installed at the factory. LOGS SEAL CAP FINISHING TEMPLATES SPLATTER GUARD TECO-SIL HEAT SHIELDS Figure 6.1 Shipping Location of Components Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 29: Securing And Leveling The Appliance

    • Secure the appliance to the floor by inserting two screws through the pilot holes at the bottom of the appliance. Figure 6.5. Heat Shields and Nailing Tabs in Installation Position Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 30: Installing Non-Combustible Facing Material

    • Use a wet or dry towel or soft brush to remove dust or dirt from facing material. • See Section 10 for finishing materials guidelines. Figure 6.7 Installing Non-Combustible Facing Material Figure 6.6 Shipping Location of Non-Combustible Board Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 31: Venting And Chimneys

    Use screws no longer than 1/2 INCORRECT in. (13 mm). If predrilling screw holes, DO NOT penetrate inner pipe. Figure 7.4 Seams Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 32: Secure The Vent Sections

    Figure 7.7 Rotate Seams for Disassembly connection point to appliance. 120º Figure 7.8 Align and Disassemble Vent Sections Figure 7.5 Securing Vertical Pipe Sections 120º Figure 7.6 Securing Horizontal Pipe Sections Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 33: Vertical Termination Requirements

    • Caulk the perimeter of the flashing where it contacts the roof surface. See Figure 7.10. • Caulk the overlap seam of any exposed pipe sections that are located above the roof line. Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 34: Horizontal Termination Requirements

    OUTSIDE SURFACE OF EXTERIOR WALL (SEE CHART BELOW) • Use an extended heat shield if the finished wall Figure 7.13 Venting through the wall thickness is greater than 7-1/4 in. (184 mm). Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 35: Electrical Information

    ACCESS THROUGH LEFT COLUMN ACCESS THROUGH FIREBOX (Prior to installation of non-combustible board) (After installation of non-combustible board) GASKET COVER Figure 8.1 Junction Box Access Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 36 Verify proper operation after servicing. WARNING! Risk of Shock! Replace damaged wire with type 105º C rated wire. Wire must have high temperature insulation. Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 37: Wiring Requirements

    SWITCH TO JUNCTION BOX 110-120 RF MODULE GRN/WHT/BLK 6 PIN CONTROL RED/BLK RED/BLK 6V DC SPLITTER BATTERY PACK APPLIANCE ON/OFF CONTROL Figure 8.3 IFT Wiring Diagram without Power Vent Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 38 WIRE ASSEMBLY CONTROL TO JUNCTION BOX 110-120 RF MODULE GRN/WHT/BLK 6 PIN CONTROL RED/ RED/ POWER VENT (OPTIONAL) ACCESSORY CABLE JUMPER WIRE Figure 8.4 IFT Wiring Diagram with Power Vent Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 39: Gas Information

    4500 feet (1370 m). • If substituting for these components, please consult Check with your local gas utility to determine proper local codes for compliance. orifice size. Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 40: Air Shutter Setting

    This is due to the different chemical compositions that make up both fuel types. In general, the LP flames may be a little shorter and much brighter than a natural gas flame. Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 41: Finishing

    COMBUSTIBLE MATERIAL 0 IN. 0 IN. 0 in. NON-COMBUSTIBLE BOARD MODEL MARQ36IN 1549 57-5/8 1464 MARQ42IN 1702 62-5/8 1591 Figure 10.1 Non-combustible Facing Diagram Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 42: Finishing Templates

    3/4 IN. Figure 10.3 Left and Right Side Finishing Template Bends Figure 10.5 Finishing Template Bends 1-1/4 IN. Figure 10.2 Top Finishing Template Bend Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 43: Mantel And Wall Projections

    6 IN. MAX. SEE SECTION 10.D FACTORY-SUPPLIED FOR REQUIRED NON-COMBUSTIBLE CLEARANCES BOARD 14 IN. MIN. COMBUSTIBLE OR FIREPLACE NON-COMBUSTIBLE OPENING WALL Figure 10.7 Non-Combustible Mantel Leg and Wall Projections Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 44 = 40-3/16 IN. (MARQ42IN) MARQ36IN MARQ42IN MIN. MARQ36IN MARQ42IN 1-1/4 IN. FIREPLACE FIREPLACE OPENING OPENING Figure 10.9 Combustible Mantel Allowance - MARQ36IN, Figure 10.10 Non-Combustible Mantel Allowance - MARQ36IN, MARQ42IN MARQ42IN Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 45: Decorative Front Dimensions For Finishing

    NOTICE: Proper clearances from the fireplace opening to any finishing material thicker than 1 inch MUST be maintained. NOTE: Finishing templates are included with this product. See Section 10.B. Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 46: Appliance Setup

    CAUTION! Risk of Injury! DO NOT put fingers under glass frame. Fingers may get pinched by glass frame during removal. Figure 11.1. Glass Clip Tool Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 47 CAUTION! Risk of Injury! DO NOT put fingers under glass frame. Fingers may get pinched by glass frame during installation. Figure 11.8. Securing Bottom Glass Clips Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 48: Remove The Shipping Materials

    Figure 11.10. Location of Glowing Embers refractory pieces. Figure 11.9. Apply Mystic Embers Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 49: Log Set Assembly

    Log #4 - 2270-704 (04) Logs can be identified by the number molded into the bottom of the log. The numbers are listed in parentheses above. Figure 1. Log Set Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 50 Log #2 (2270-703): Log #2 is positioned on the front left grate using groove depicted in Figure 6. Ensure the log is slid forward to bend in grate tine. The log also mates with the center grate tine using feature shown in Figure 6. Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 51 Figure 8. Log #3 (MARQ36IN 2270-702) (MARQ42IN 2271-702): Log #3 is positioned on the base refractory, slid tight to the far left grate tine shown in Figure 9, resting on the recess in Log #1 and the pilot shield. See Figure 9.
  • Page 52 Log #1 and Log #5. Log #7 will rest on the top of Log #2 and mate with the middle grate tine. See Figure 16. Figure 16. Log Set Installed Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 53: Log Placement Instructions

    Log #4 - 2271-704 (14) Logs can be identified by the number molded into the bottom of the log. The numbers are listed in parentheses above. Figure 1. Log Set Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 54 Log #2 (2271-703): Position Log #2 on the front left grate using groove shown in Figure 6. Ensure the log is slid forward to bend in the grate tine. The log will also mate with the center grate tine using feature shown in Figure 6. Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 55 Log #4 (2271-704): See bottom of Log #4 in Figure 10. The two grooves will mate with the grate tines as shown in Figure 11. The log will contact the base refractory, side refractory panel, and the tip of Log #1, creating 5 total contact points. Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 56 Log #1 and Log #5. Log #7 will rest on top of Log #2 and mate with middle grate. See Figure 17. Figure 17. Log Set Installed. Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 57: Led's

    Contact your dealer or Hearth & Home Technologies if the barrier is not present or help is needed to properly install one. For more information refer to the instructions supplied with your decorative front. Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 58: Reference Materials

    (254 mm) 14 in. (356 mm) 5 in. 12 in. (127 mm) (305 mm) 6 in. (152 mm) DVP-HVS (Vent Support) DVP-WS (Wall Shield Firestop) Figure 12.1 DVP vent components Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 59 (305 mm) 79 mm 117 mm Length DVP-TRAP 5-3/8 in. 9-3/8 in. Trap2 Horizontal Termination Cap 137 mm 238 mm DVP-TRAP2 DVP-TRAP1 DVP-TRAPK2 DVP-TRAPK1 Figure 12.2 DVP vent components Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 60 13-7/8 in. 9-1/2 in. Cap Shield (352 mm) (241 mm) 26 in. 660 mm 14 in. (356 mm) DVP-HSM-B Extended Heat Shield DRC-RADIUS Cap Shield Figure 12.3 DVP Vent Components Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 61 9-3/16 IN. (233 mm) 13-5/8 IN. 16-11/16 IN. 16-11/16 IN. (346 mm) 424 mm (424 mm) 12-1/2 IN. SLP-LPC (318 mm) SLP Low Profile Cap Figure 12.4 DVP vent components Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 62 60 FT PV Wire Harness PVI-WH60 area. 80 FT PV Wire Harness PVI-WH80 100 FT PV Wire Harness PVI-WH100 PVLP-HS PVLP-BEK Heat Shield Brick Kit Figure 12.5 PVLP-SLP Vent Components Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...
  • Page 63: Accessories

    Street West, Lakeville, MN 55044 www.majestic.com Please contact your Majestic dealer with any questions or concerns. For the location of your nearest Majestic dealer, please visit www.majestic.com. Printed in U.S.A. - Copyright 2016 Majestic MARQ36IN, MARQ42IN Installation Manual • 2270-980 Rev. B • 10/16...

This manual is also suitable for:

Marq42in

Table of Contents