B. General Operating Parts
Figure 3.2 references the general operating parts of the
appliance and the section of this manual in which they are
discussed.
Figure 3.2 General Operating Parts
C. Fuel Specifications
WARNING! Risk of Fire or Explosion! Appliance must
be set up for compatible gas type!
• This appliance is designed to operate on either natural
gas or propane. Make sure the appliance is compatible
with gas type selected for installation site.
• Conversions must be made by a qualified service
technician using Hearth & Home Technologies specified
and approved parts.
8
DECORATIVE
BARRIER FRONTS
(NOT SHOWN)
SECTION 4.B.
HEARTH
CLEAR SPACE
SECTION 3.A.
Majestic • MARQ42STIN Owner Manual • 2272-981 Rev. L • 12/20
MANTEL
FIXED GLASS ASSEMBLY
(NOT SHOWN)
SECTION 4.B.
D. Good Faith Wall Surface/TV Guidelines
FIREPLACE
OPENING
Figure 3.3. Good Faith Wall Surface Temperatures Above Appliance
NOTICE:
Surface
temperatures listed above are taken with
a temperature measuring probe as prescribed by the test
standard used for appliance certification. Temperatures
on walls or mantels taken with an infrared thermometer
may yield increased temperatures of up to 30 °F (17 °C) or
more depending on the thermometer settings and material
characteristics being measured. Use appropriate finishing
materials that are able to withstand these conditions.
For additional finishing guidelines, see Section 10 in the
appliance installation manual.
TO CEILING
105 °F
116 °F
123 °F
36 in.
124 °F
30 in.
129 °F
24 in.
18 in.
157 °F
12 in.
6 in.
MEASUREMENTS FROM
TOP EDGE OF THE OPENING
APPLIANCE FRONT