Panasonic PT-53WX54J Service Manual page 139

Hdtv monitor
Hide thumbs Also See for PT-53WX54J:
Table of Contents

Advertisement

2. Lay CRT face down on a soft cloth.
3. Note position of yoke with centering tabs and remove from defective
CRT.
4. Remove CRT DAG ground from defective CRT. Mount it on the
replacement CRT exactly as it was on the defective CRT.
Note:
Replacement CRT is supplied with H.V. anode lead attached.
5. Wire the anode lead wire.
6. Install yoke with other CRT neck assemblies on CRT neck in the same
order and position as removed from the defective CRT.
7. Press yoke against bell of CRT and tighten the clamp just snug
enough so it will not easily shift.
8. Assemble CRT focus lens assembly to new CRT with (4) screws. Make
sure focus lens adjustment nut is in the same location as on other
CRT focus lens
Note:
Please assemble with screws in the order shown and tighten with the same torque.
Optical block position adjustment
CRT screw tightening order
Optical block position
36