Battery Replacement
1. Remove the spark plug boot from spark plug.
2. Remove the nut and bolt from the negative(-) post first, then the positive(+) post.
3. Loosen and remove the fasteners(A) on the battery holding bracket.
4. Remove the battery and recycle.
5. Install the new battery with the following specification:
12V sealed lead acid 15AH
LXWXH:7,09X2,95X6,5in. (180X75X165mm)
6. Connect the red positive (+) battery cable to the battery first.
7. Connect the black negative (-) battery cable to the battery second.
8. Cover the posts with boots provided.
9. Install the spark plug boot onto spark plug.
Battery Charging
The battery powers the starter motor and control module. This portable generator is equipped
with an automatic battery charging circuit. The battery will receive charging voltage only when
the engine is running. The battery will maintain a proper charge if the portable generator is used
on a regular basis (about once every two weeks). If it is used less frequently, the battery should
be connected to a trickle charger (not included) or battery maintainer (not included) to keep the
battery properly charged. If the battery is not able to start the engine, the battery must be
connected to a standard automotive style battery charger for re-charging before it can be used.