Always disconnect the appliance from the
electricity main before proceeding with any
servicing operation.
7) REPLACING THE ELECTRICAL
COMPONENTS
For access to the various parts, remove the hotplate
from the top of the cabinet. Then overturn it, unscrew
screw and remove under part.
After these actions is possible to work on the
plates, commutators, clamps and input cable.
POWER OF ELECTRICAL COMPONENTS DENOMINATIONS W
Denominations
Normal plate 7 positions
with the protector
Normal plate 7 positions
with the protector
Rapid plate 7 positions
Rapid plate 7 positions
**ECelectric cooking: Energy consumption per kg calculated according to Regulation (EU) 66/2014.
Cable type
Rubber H05 RR-F
Polycroropene H05 RN-F
(*) keeping in mind the contemporaneousness factor
SERVICING
TYPE AND SECTION OF THE POWER CABLES
N.B. In case of substitution of the input cable,
the installer must keep the "earth" conductor
longer than "live" ones, and must respect the
cautions in paragraph "Electrical connection".
To reassemble the appliance repeat the inverse
process.
8) TECHNICAL CHARACTERISTICS OF
THE ELECTRICAL COMPONENTS
To facilitate the job of the installer we present a
scheme with the characteristics of the components.
POWER
Ø (cm)
(W)
14,5
1000
18,0
1500
14,5
1500
18,0
2000
Single phase power
230 - 240 V~
3 X 1.5 mm
3 X 1.5 mm
9
EC
electric cooking**