- GENERAL FEATURES
NIKE MINI is a wall-hung conventional flue for central heating and the production of domestic hot
water that stands out for its compact dimensions (773 x 450 x 250).
The boiler features a microprocessor-controlled electronic board that electronically controls burner
ignition, central heating and d.h.w. temperature and flame modulation.
The unit has a working heat output of 20.000 kcal/h (23,3 kW) and features a standard antifreeze safety
device that ensures operation with temperatures as low as - 5°C.
The hydraulic circuit features a copper water-gas exchanger, a 3-way hydraulic valve and a
STAINLESS-STEEL plate exchanger for the instantaneous production of domestic hot water.
- MAIN DIMENSIONS AND CONNECTIONS
STNME ed 07/03
NIKE Mini
1
Technical documentation
Conventional flue wall-hung boiler
with instantaneous production of
D.H.W. and compact dimensions
NIKE Mini
DIMENSIONS (mm)
HEIGHT
WIDTH
773
450
CONNECTIONS
GAS
D.H.W.
G
U
1/2 "
1/2 "
V - power supply
G - gas supply
U – domestic hot water outlet
E – domestic hot water inlet
R - system return
M - system flow
DEPTH
250
SYSTEM
E
R
M
1/2 "
3/4 "
3/4 "