RuiDeng DPS8005 Operating Instructions Manual

RuiDeng DPS8005 Operating Instructions Manual

Constant voltage / constant current programmable power supply
Hide thumbs Also See for DPS8005:

Advertisement

Quick Links

Constant Voltage / Constant Current
Programmable Power Supply

General Information

The programmable Power supply offers constant Current and constant Voltage and combines
both analog and digital technology in an integrated and advanced design.
The fully adjustable output ranges from 0-80.00V in 0.01V (10mV) steps and the fully adjustable
Current Limited output ranges from 0-5.100A in 0.001A (1mA) steps.
The unit offers non-volatile power off parameter storage and 10 programmable preset memory
Data Groups with a quick recall function for groups 1 and 2.
The digital control interface offers a comprehensive feature set not available on analog only
power supplies. The keypad and rotary control offer simple input and selection of all required
settings whilst the full colour LCD offers detailed display of the extensive but easily read
information relating to system operation and performance. Items that can be displayed include a
precision voltmeter and ammeter, preset Voltage, output Voltage, preset Current Limit, output
Current, output Power and Data Group selection parameters and menus. Notification icons and
text include indications such as output enabled or disabled, Constant Current or Constant Voltage
mode of operation, abnormal condition warning, keypad locked or unlocked state and the Data
Group in use. The Data Setting interface allows full adjustment of Over-Current, Over-Voltage and
Over-Power protection values, Data Group settings and LCD brightness. The unit offers a
technologically advanced design presented in a very compact size that is both visually appealing
and easy to operate.

Technical parameters

Input Voltage range: 10.00-90.00V
Output Current: 0-5.100A
Product Weight: 150g
Display module enclosure cutout size: 71mm*39mm
Output Voltage resolution: 0.01V (10mV)
Output Voltage accuracy: ± (0.5% + 1 digit)
NOTES:
1. You must ensure that the input Voltage is at least 1.1 times higher than the output Voltage.
2. When the unit mounted in an enclosure it is absolutely vital to ensure appropriate
ventilation for heat dissipation.
Output Voltage range: 0-80.00V
Output Power range: 0-408W
Display module size: 79*43*54(mm) (L*W*H)
Output Current resolution: 0.001A (1mA)
Output Current accuracy: ± (0.5% + 2 digits)
Model: DPS8005

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DPS8005 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for RuiDeng DPS8005

  • Page 1 Constant Voltage / Constant Current Programmable Power Supply Model: DPS8005 General Information The programmable Power supply offers constant Current and constant Voltage and combines both analog and digital technology in an integrated and advanced design. The fully adjustable output ranges from 0-80.00V in 0.01V (10mV) steps and the fully adjustable Current Limited output ranges from 0-5.100A in 0.001A (1mA) steps.
  • Page 2 Connection details IN+ : Input positive IN - : Input negative OUT+: Output positive OUT- :Output negative Note: The input Voltage range is DC 10.00-80.00V. 80.00V DC is the maximum input Voltage limit. Always ensure an adequate safety margin and ensure that your OFF LOAD input supply Voltage does not exceed the maximum allowed.
  • Page 3 17. Output enabled or disabled prompt 18. Preset output Voltage. 19. Preset output Current Limit. 20. Preset Over-Voltage Limit. 21. Preset Over-Current Limit. 22. Preset Over-Power Limit. 23. Preset screen brightness level. 24. Preset Data Group number. 25. The actual value of the output Voltage and output Current.
  • Page 4 same way as used in the main interface. Press the SET key to return to the menu options and press the SET key again to exit. Set the Protection Values. Press V/↑or A/↓to step up or down through the menu options to select S-OVP (Over-Voltage Protection), S-OCP (Over-Current Protection) or S-OPP (Over-Power Protection) limits.
  • Page 5 and anticlockwise decreases the value. After setting the desired value press and hold the SET key until the Data Group number is shown on the right hand side of the screen. The data value is now saved to the indicated Data Group number.
  • Page 6 From the main interface, press and hold the SET key more than 3 seconds, M0 will be displayed on the right side of the screen. Turning the rotary control allows selection of the required Data Group (M1 to M9). To activate the selected Data Group press the SET key.

Table of Contents