Quick Start Guide
C.A 5292 / C.A 5293, ASYC IV
Portable 100,000 cts Graphic Multimeter
This guide is available in various laguages on the CD
supplied with the instrument.
We thank you for your confidence in the quality of your products.
A complete user's manual is also provided on the CD supplied
with the instrument.
It can be download from : www.chauvin-arnoux.com.
Attention : for your safety and to protect your property,
please read carefully the safety datasheet enclosed with
your instrument.
This multimeter complies with the EN 61010-2-033 CAT IV
600 V – CAT III 1000 V, safety standard on double insulation for
electronic measuring instruments. IP 67 as per standard
IEC 60529. Then, if the instrument is immersed, it must be dried,
in particular the terminal block, before it can be used again.
This instrument has been designed for use indoors :
- in an environment with pollution level 2,
- at an altitude of less than 2000 m,
- at a temperature between 0°C and 50°C,
- with relative humidity < 80 % up to 35 °C.
It can be used for measurements on the circuits of :
- Category III installations for voltages up to 1,000 V
(AC or DC) relative to earth.
- Category IV installations for voltages up to 600 V
(AC or DC) relative to earth.
For safety reasons, only use suitable cords supplied with the
instrument: they comply with the EN 61010-031 standard.
Before each use, make sure that they are in perfect condition.
When the instrument is connected to the measuring circuits,
never touch a terminal which is not in use. Use only suitable
accessories delivered with the instrument or approved by the
manufacturer.
If the measurement category of the accessory is different from
that of the instrument, the lowest category applies to the unit.
X04857A02_Ed1_11/2018
FREQUENCY : Hz
1. Activate Hz
V input
COM input
2. Select Range ±, frequency
range and
< 200 kHz or
> 200 kHz
By the keys
.
3. Select Meas..., then
 REL relative measurement
 SURV for tiem stamped
MIN/MAX/AVG
 SPEC to obtain the
specifications.
 MEAS+ to select a
secondary function among :
MATCH, DCY, PER,
PW+/-, CNT+/-
C.A 5292
Display
Graphic color (70 x 52)
1 set of AA/R6 batteries or
Power supply
1 set of 4-Ni-Mh storage batteries
Counts
100 000
Communication
IR / USB (Bluetooth, optional)
FUSE AND BATTERIES OR RECHARGEABLE
BATTERIES
Fuse : 11 A : 10 x 38 – 1000 V
F – breaking capacity : > 18 kA
4 batteries : 1.5 V AA LR6 or batteries 1.2 V Ni MH LSD
TERMINAL BLOCK
Terminal block : with 3 4-m banana inputs and an optical connector for
USB communication.
DISPLAY OF THE CONNECTION ON THE SCREEN
RESISTANCE : Ω, DIODE, CONTINUITY
V input
COM input
1. Activate Ω, by pressing this key :
 F2 accesses
(continuity)
 F3 accesses 100 Ohm range
 F4 selects the diodes (4 V or 26 V diode test) or
subsequent presses
2. Select Meas..., then
 REL relative measurement
 SURV for time-stamped MIN/MAX/AVG
 SPEC to obtain the specifications
 MEAS+ for the MATH secondary function
VOLTAGE : VAC, VDC, VAC+DC
C.A 5293
1. Activate « V », then press F1,
F2, F3, F4 to select the
coupling :
 AC,
 DC,
 AC+DC or
 VlowZ.
Configuration SETUP  MESURE
to adjust the parameters : filters,
impedance, reference...
2. Graphic mode (default), but
select Meas for another display
 GRAPH graphical history of
the measurements
 REL
relative measurement
 SURV for MIN/MAX/AVG
(time stamped)
 SPEC to get the specs
 MEAS+ to select a secondary
function
 WFORM wave form
3. Select Mem... to save or stop (up to 30 000 measurements,
depending on model)
Consult data by long press on Mem...
GRAPHIC DISPLAY OF Mem IN VAC+DC MODE
V input
1. Activate
Pressing :
 F1 accesses Range+
 F2 accesses Range-
Select ranges by those keys
2. Select Meas..., then :
 REL relative measurement
 SURV for time-stamped MIN/MAX/AVG
 SPEC to obtain the specifications.
V input
COM input
Delimitation of the
enlarged area.
Use F1/F2/F3 to
select the object to
be modified
(cursor, Zoom or
Trace) and the
arrows to change
the value.
CAPACITY :
COM input
RUN is displayed
when the
measurements is
running and OL is
diplayed if the value
is > range or if there
is a short-circuit.
, by pressing this key.
.

Advertisement

loading

Summary of Contents for Chauvin Arnoux 5292

  • Page 1 Quick Start Guide VOLTAGE : VAC, VDC, VAC+DC C.A 5292 C.A 5293 C.A 5292 / C.A 5293, ASYC IV V input COM input Display Graphic color (70 x 52) 1. Activate « V », then press F1, F2, F3, F4 to select the...
  • Page 2 TEMPERATURE DIRECT MEASUREMENT OF CURRENT : A SECONDARY MODES ACCESSIBLE VIA MEAS… °C, °F, K in TL/TJ or Pt100/Pt1000 V input COM input COM input A input Activate or deactivate the selected mode by pressing the Display in REL mode : MEAS…...

This manual is also suitable for:

5293P01196802P01196803