Performance Data Sheet - Zenith HydroTap G5 Installation Instructions Manual

Command centre
Hide thumbs Also See for HydroTap G5:
Table of Contents

Advertisement

Performance data sheet

Zenith HydroTap UltraCare UV-C Module
809283 (MicroPurity)
Is tested and certified by WQA to NSF/ANSI 55
for Class B disinfection. When the UV-C Module
is used with a Zenith HydroTap System, flow
rate must be at maximum of 2.8 L/min or less to
be valid.
Manufacturer
Zip Water (Aust) Pty. Ltd
67 Allingham Street, Condell Park NSW 2200
Australia. Tel: +61 2 97 96 3100
Performance data
Testing Conditions and Results:
Flow Rate: 2.8 L/min (0.74 gpm)
Max. Pressure: 830 kPa (60 psi)
Capacity: 24,000 litre / 24 months
Operating Conditions:
Electrical characteristic: 12 VDC, 1.6 A
Max. Operating Temperature: 50°C
Replacement UV-C module:
809283 (Spare part number: 96863)
Class B system:
This system or component conforms to NSF/ANSI 55 for the supplemental
bactericidal treatment of disinfected public drinking water or other drinking
water that has been tested and deemed acceptable for human consumption
by the state or local health agency having jurisdiction. The system is
only designed to reduce normally occurring non-pathogenic, nuisance
microorganisms. Class B systems are not intended for the disinfection of
contaminated water. While testing was performed under standard laboratory
conditions,actual performance may vary.
General UV-C module installation instructions
See pages 19-21.
807042NZ v1.02 08.22 HydroTap G5 UltraCare Install Instructions