Download Print this page
Eaton Vickers FG-3 10 Series Quick Start Manual
Eaton Vickers FG-3 10 Series Quick Start Manual

Eaton Vickers FG-3 10 Series Quick Start Manual

Flow controls

Advertisement

Quick Links

Vickers
Flow Controls
Pressure Compensated Flow
Control Valves
F(C)G-3, 10 Series; ISO 4401, Size 03/NFPA D01
A
P B
Basic Characteristics
Max. flow rates
. . . . . . . .
1,0 to 18 L/min
(0.42 to 4.75 USgpm),
dependent on model
Max. pressure
. . . . . . .
315 (4500 psi) or
160 bar (2325 psi),
dependent on model
Functions
. . . . . .
In line, with or without
reverse flow check and
anti-jump feature
Rev. 8/97
®
General Description
These pressure compensated valves are
designed to provide adjustable controlled
flow rates independent of changes in inlet
and/or outlet pressures above a minimum
pressure differential. Models are available
with or without integral reverse flow check
valves. Those with check valves are
optionally available with an anti-jump
feature designed to eliminate transient
surges above the controlled flow rate
setting whenever flow is first directed to
the inlet port A.
Functional Symbols
FG-3-***-*-10 models, without reverse
flow check
B
Simplified symbol
A
Detailed symbol
FCG-3-***-*-10 models, with reverse
flow check
B
A
All models have rotary adjustment of
controlled flow and can be supplied with
or without an integral key-lock feature.
The construction of a typical model with
integral check valve and anti-jump feature
is shown opposite. Its operation is the
same as for similar valves described in
the "Industrial Hydraulics" manual
although the spring-loaded hydrostat is
functionally located downstream of the
adjustable restrictor, as shown in the
"Functional Symbols" section.
FCG-3-***-A-*-10 models, with reverse
flow check and anti-jump feature
B
A
A
P
Typical
directional valve
B
Note: FCG-3-***-A models are designed
primarily for meter-in applications where the P
port can be connected to an upstream point
that provides continuous pilot pressure to the
A
hydrostat to prevent "jump". Consult your
Vickers representative about alternative
applications.
B
B
P
P
A
T
GB-514A

Advertisement

loading
Need help?

Need help?

Do you have a question about the Vickers FG-3 10 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Eaton Vickers FG-3 10 Series

  • Page 1 ® Vickers Flow Controls Pressure Compensated Flow Control Valves F(C)G-3, 10 Series; ISO 4401, Size 03/NFPA D01 General Description All models have rotary adjustment of controlled flow and can be supplied with These pressure compensated valves are or without an integral key-lock feature. designed to provide adjustable controlled The construction of a typical model with flow rates independent of changes in inlet...
  • Page 2 Model Code F(C)G -3- *** (-A) - * - 10 Type Anti-jump feature (FCG model option) FCG = Flow control with reverse flow Omit when not required and for all FG check models. FG = Flow control without reverse flow check Controlled flow adjustment Max.
  • Page 3 Performance Data Thermal stability of controlled flow, Typical with petroleum oil at 36 cSt (170 SUS) and at 50_C (122_F) typical example: Controlled Flow, F(C)G-3-16/32 Models Flow set at 20_C (68_F) ..0,25 L/min Angular rotation (degrees) from zero (0.07 USgpm) USgpm L/min...
  • Page 4 Installation Dimensions in mm (inches) 3rd angle 63,5 (2.5) projection 60,0 (2.36) Ø 5,5 (0.217 dia) To adjust controlled flow rate: (0.12) For valves with key lock, first unlock by turning key counter-clockwise. Turn adjustment knob clockwise to increase flow 46,5 rate, or counter-clockwise to decrease flow (1.83)

This manual is also suitable for: