Dear Customer Thank you for buying our range hood. Please read the user manual carefully and store in a handy place for later reference. This hood is designed for install on walls. Read the following carefully to avoid damage or injury. SAFETY AND WARNINGS ●...
Page 4
or hot air duct containing combustion fumes from burning gas or other fuels. Confirm that room ventilation is appropriate with the local authorities. ● The air must not be discharged into a flue that is used for exhausting fumes from appliances burning gas or other fuels ●...
external timer or separate remote control system. ● There shall be adequate ventilation of the room when the hood is used at the same time as appliances burning gas or other fuels. Ensure that the negative pressure of the installation site does not exceed 4 Pa (0.04 mbar) to ensure combustion fumes are not drawn back into the room.
INSTALLATION 660mm top of cooking surface Positioning Fixing dimensions WARNING! these instructions may result in electrical hazards.
Page 8
Drilling holes ● Mark the location for flue cover wall mounting brackets, rangehood mounting points and anti-tilt fixing points above the rangehood using the base as the reference point (Fig. 1). Fig.1 Attach chimney brackets and hood mounting screws ● Attach the upper hood mounting screws in the locations shown in Fig.2.
Page 9
Screws ST3.9 x 32mm Fig.2 Attached hood on wall ● Remove the aluminium filters from the rangehood body and hang it on the ST3.9 x 32mm screws then secure at the anti-tilt locations as indicated in Fig. 3. Fig.3...
Page 10
Connect ducting adapter ● Connect Ø120mm ducting adapter to the blower outlet and use ST3.9 x 13mm screws to fix it to the range hood (Fig. 4). Screws ST3.9 x 13mm Ø120mm Ducting adapter Fig.4 Fixing flexible duct ● If need exhaust air to the outside. Connect Ø125 mm flexible duct to the adapter and fix it (Fig.
Page 11
Attach the chimney Fig.6 Connect ducting adapter ● Fix the chimney to the top bracket using the ST3.9 x 13mm screws. Connect top of the ducting tube to vent kit as per manufacturers instructions (Fig. 7). ● Install back the aluminium filters to rangehood, and for Stainless Steel appliance, remove the protection film from rangehood and chimney.
OPERATING INSTRUCTIONS Control panel features 1 – Light switch. 2 – Lighting control lamp. 3 – 3 position switch controls the motor (1st, 2nd, and 3rd speed). 4 – Motor control lamps. TIMER:To operate the canopy timer, having selected the speed, press the button for 2 seconds until the luminous LED blinks.
Page 13
FUSE 10’ from the manufacturer. 1 MONTH ≤ 65ºC...
Replacing Activated charcoal filters Replace Activated charcoal every 3 months 3 MONTHS Troubleshooting Problem Possible cause Solution Excessive vibration. The appliance is not installed Take down the appliance and check properly on the brackets. The fan blade is damaged. Switch off the appliance. Repair to The light is on, but the The fan blade is jammed.
Recycling & disposal The symbol on the product or on its packaging indicates that this product may not be treated as household waste. Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment.