32 | Vocollect Talkman A700 Product Guide
A700 Battery Charger
A700 Device Charger and Battery Charger Wall Mount
The A700 charger and the A700 battery charger are ready for mounting on a standard DIN rail without any
customer modifications. A DIN rail must be installed on a wall in a suitable location. Vocollect offers a DIN
rail suitable for mounting a single charger, but customers may choose to purchase rails from other suppliers
as long as the rails meet Vocollect specifications. Consider the following before wall mounting your charger.
•
Customer assembly required for the rail wall mount.
•
Customer assumes all responsibility for the installation of charger units.
•
Installer must verify that the installation meets all local building codes.
•
Avoid potential hazards (electrical wires, waterlines, and similar building components) when drilling into
the wall.
•
Avoid blocking power outlets and other wall receptacles when installing the rail and charger.
•
Anchoring a wall mount rail to a wall stud generally results in a more stable installation. If you drill into a
wall stud, do not use a screw anchor in that hole.
•
If you are mounting two chargers side by side, you must leave at least 1 in. (2.54 cm.) of space between
the two units to allow clearance for the locking arms.
•
Rails must be anchored to the wall at least 12 in. (30.5 cm.) from the floor to allow for proper attachment,
seating, and removal of the charger unit.
•
If you are mounting a charger directly above another charger, Vocollect recommends clearance of at least
10 in. (25.4 cm.) between DIN rails.
Part Number in Diagram
1
Confidential: For informational use by Honeywell resellers and customers only
Figure 7: A700 12-Bay Battery Charger
Figure 8: A700 charger - back view
Description
power supply