Troubleshooting
DRO 100
where measurements can again be displayed, selecting a lower display resolution,
or zeroing the display.
This error may also occur when using the automatic compensation routine while
setting the LEC parameter. An error indicates that the calculated compensation
factor was outside the acceptable range of -9999 to +9999, and usually is the
result of incorrectly entering data. Clear the error and return to the beginning of
the linear error compensation routine. Refer to page 8.
Data Logging
The readout collects information about itself while it is being used. This
information is stored in memory for review at a later time.
RAD
Press and hold the
key until the software version is displayed. Then press
DIA
the
and
keys simultaneously. Use the
key to cycle through the
ZERO
MM
SETUP
following information.
Power on time—displayed in decimal hours.
Scale travel distance—the travel distance for each axis is scrolled one after the
other.
Last 3 errors—the most recent three errors are remembered and messages for
the errors are scrolled one after the other.