Replacing the Drip Pad

BEFORE STARTING WORK, BE SURE THE POWER TO THE WINE GUARDIAN
COOLING UNIT AND HUMIDIFIER ARE TURNED OFF. MAKE SURE THE POWER
CORD IS DISCONNECTED FROM THE POWER SOURCE.
1.
Start by disconnecting the electrical power and shutting off the water supply.
2.
Remove the access panel at the back of the humidifier.
3.
Remove the drip pad by lifting up on the spring-loaded drip tray.
4.
To clean the drain, pour some hot water mixed with a cleaning solution into the
drain area of the humidifier to flush the dirt down the drain tube.
5.
Check the humidifier pad. If dirty or excessive mineral deposits are present,
install a new evaporative pad. Replace the pad by lifting up on the spring-loaded
drip tray.
Note: the pad must be installed in the correct position. There is a black spot painted on
one end of the pad. This is the top of the pad and must be installed with the black spot
UP, next to the distribution tray. There is no inlet or outlet side for the airflow, only the
requirement that the black spot be on the top.
6.
Be sure the water feed tube is aimed into the center of the distribution tray.
7.
Turn on the water and power.
8.
Check for operation. See instructions under Start-Up. Be sure water is flowing
into the distribution tray and flows freely out the holes and over the pad. If water
flow is not a steady flow, the strainer and/or orifice may need service.
9.
Re-install the humidifier access cover