OUTP:PROT
There are two output protection commands that do the following:
Clears any OV (overvoltage), OC (overcurrent, unless set via external voltage control),OT
OUTP:PROT:CLE
(overtemperature), or RI (remote inhibit) status conditions. If the power supply is configured with
the Agilent 59510A/llA Relay Accessory, it will be restored to the state it was in before the
protection circuit tripped.
OUTP:PROT:DEL
Sets the time that a change in CV, CC, or UNREG condition must appear at the output before that
change is recorded in the Status Operation Condition register. The delay prevents momentary output
changes that can occur during reprogramming from being registered as events by the status
subsystem.
Command Syntax
Parameters
Default Sufflx
Examples
Query Syntax
Returned Parameters
OUTP:REL[:STAT]
This command is valid only if the power supply is configured for the optional Agilent 59510A and Agilent 59511A Relay
Accessory. Programming ON closes the relay; programming OFF opens it. If the power supply is not configured for either
device, the command generates an error.
Command Syntax
Parameters
*RST Value
Examples
Query Syntax
Returned Parameters
OUTP:REL:POL
This command is valid only if the power supply is configured for the Agilent 59511A Relay Accessory. The NORM al
command causes the device output polarity to agree with that of the power supply. Programming REV causes the polarity of
the device to be opposite to that of the power supply. If the power supply is not configured for the Agilent 59511A, either
command generates an error.
Command Syntax
Parameters
*RST Value
Examples
Query Syntax
Returned Parameters
Standard Commands for Programmable Instruments (SCPI)
98
ut: PROT ection: CLE ar
OUTP
ut: PROT ection: DEL lay <NRf+>
OUTP
OUTP:PROT:CLE
(None)
OUTP:PROT:DEL
See "DI,Y" in Table 3-7 of Section III.
S
OUTP: PROT: CLE OUTPUT: PROTECTION: CLEAR
OUTPUT:PROTECTION:DELAY 75E-l
OUTP:PROT:DELMIN
(None ) OUTP:PROT:DEL?
OUTP:PROT:CIE
OUTP:PROT:DEL? MIN OUTP:PROT:DEL? MAX
<NR3> OUTP:PROT:DEL
OUTP:PROT:DEL? MIN
programmable delays.
ut :REL ay [:STATe] <bool>
OUTP
0 or OFF
I or ON
0
OUTP: REL 1 OUTPUT: RELAY OFF OUTPUT: RELAY: STATE OFF
OUTP:REL?
<NR.1> 0 or 1
ut :REL ay :POL arity {NORMalREV erse }
OUTP
or REVerse
<CRD> NORMal
NORM
OUTP: REL: POL NORM OUTPUT: RELAY: POLARITY REVERSE
OUTP:REL:POL?
or REV
<CRD> NORM
OUTPUT:PROT:DELAY MAX
returns value of programmed delay .
and OUTP:PROT:DEL? MAX return the minimum and maximum