Fault Finder - Wickes THERMOSTATIC POWER SHOWER Product Manual

Table of Contents

Advertisement

Malfunction
Maximum shower
temperature too hot.
Shower temperature too
cold.
Blend temperature
unstable.
Low or no water flow
Shower runs cool after a
short time (1 -2 minutes)
then flow splutters.

FAULT FINDER

Cause
Incorrect setting of
maximum temperature.
Hot water cylinder
temperature less than
10°C above shower
temperature,
Maximum temperature
incorrectly set.
Spray plate blocked.
Inlet filter blocked.
Isolating valve partially
closed.
Plumbing system fault.
Isolating valves closed.
Inlet filters blocked.
Check valve fitted
incorrectly.
Appliance sited above
cold water storage
cistern.
Plumbing system fault
(airlock).
Air ingress into hot
pipework.
20
Remedy
Reset maximum
temperature.
Adjust cylinder
temperature
(Recommended not to
exceed 6O°C BS6700).
Reset maximum
temperature.
Clean spray plate.
Contact your installer.
Open valve.
Contact your installer.
Open valves.
Contact your installer.
Contact your installer.
The appliance is not
suitable for negative
head installations.
Contact your installer.
Refer to system diagram
section "INSTALLATION
REQUIREMENTS" for
correct connection
method.

Advertisement