Safety notes Please read this manual carefully and completely before you use the device for the first time. The device may only be used by qualified personnel and repaired by PCE Instruments personnel. Damage or injuries caused by non-observance of the manual are excluded from our liability and not covered by our warranty.
Display description Possible display Meaning Displayed measured value is stable Zero Displayed measured value is the zero point Tara Displayed measured value is tared HOLD Displayed measured value is frozen Measured value in pounds Measured value in kilogrammes Measured value is displayed in a user-defined unit Indications Possible display Meaning...
Zero point To set the zero point, press the key on the remote control or hold down the key on the scales. Note: If the attached load is in motion, tared or outside the manual zero range, "Err" is displayed. Taring To tare the weight, press the key on the remote control or press and release the...
6.5.3 Delete all saved values To delete all saved values, first press the key on the remote control and then press the key. As soon as "CLR" is shown on the display, all values are deleted. Change unit To set the unit, press the F2 key on the remote control or briefly press and hold the key on the scales.
Advanced settings Note: The advanced settings should only be used by advanced users as incorrect parameterisation can cause problems. Changing the parameters does not change the given specifications. key twice. “P0000" is then displayed. Use the arrow To open the advanced settings, press the keys on the remote control to enter the password P0258 and confirm the entry with the key.
Page 14
This function measures the weight On = switched on based on the last zeroing. When this Off = switched off (default) function is active, automatic zeroing is deactivated. Here you can set the measuring 0 = off rate. 1 = weakest (default) If the weight is unstable, a high value 2 = weak should be selected.
Adjustment If the scales show incorrect values, it can be adjusted. An adjustment should only be carried out by an advanced user. Make sure in advance that you have calibrated weights available to achieve an accurate result. Note: Changing parameters does not change the specifications. key twice.
Battery The battery status is displayed each time the scales are switched on and off. As soon as the batteries are flat, they must be replaced with new ones. For battery replacement, there are two battery compartments on the back of the scales that can be opened with a screwdriver. Two 1.5 V AA batteries must be inserted in each battery compartment.
Page 17
PCE Instruments contact information Germany France Spain PCE Deutschland GmbH PCE Instruments France EURL PCE Ibérica S.L. Im Langel 26 23, rue de Strasbourg Calle Mayor, 53 D-59872 Meschede 67250 Soultz-Sous-Forets 02500 Tobarra (Albacete) Deutschland France España Tel.: +49 (0) 2903 976 99 0 Téléphone: +33 (0) 972 3537 17 Tel.