Nittan Evolution-Advanced EV-DP Instruction Manual

Analogue addressable dual wavelength photoelectric smoke sensor

Advertisement

Quick Links

evolution-advanced
EV-DP
PHOTOELECTRIC SMOKE SENSOR
ANALOGUE ADDRESSABLE
DUAL WAVELENGTH
INSTRUCTION MANUAL
LPCB REF: 041f/02
Quality System Certificate No. 041
Assessed to BS EN ISO 9001:2002
Document No. NISM/EV-DP/01
Date
NOV 2003

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Evolution-Advanced EV-DP and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Nittan Evolution-Advanced EV-DP

  • Page 1 Document No. NISM/EV-DP/01 Date NOV 2003 evolution-advanced EV-DP ANALOGUE ADDRESSABLE DUAL WAVELENGTH PHOTOELECTRIC SMOKE SENSOR INSTRUCTION MANUAL LPCB REF: 041f/02 Quality System Certificate No. 041 Assessed to BS EN ISO 9001:2002...
  • Page 2 INSTRUCTION MANUAL evolution..The new EV-DP advanced analogue addressable smoke sensor forms part of a brand new range of analogue addressable fire sensors from Nittan (UK) evolution-advanced. Ltd called The EV-DP together with the EV-PH, EV-H, EV-P and EV-UV are all elegantly designed, low profile fire sensors which are aesthetically pleasing, thus enabling them to blend unobtrusively into modern working environments.
  • Page 3: Section 1 - Introduction

    DUAL WAVELENGTH PHOTOELECTRIC SMOKE SENSOR PAGE: ISSUE: INSTRUCTION MANUAL Section 1 - INTRODUCTION CONTENTS:- The EV-DP is an attractively-styled, low profile photoelectric smoke sensor for use with Nittan Section 1 Introduction - Page 2 evolution ' protocol control panels. Section 2 Sensor Models...
  • Page 4: Section 4 - Installation

    evolution-advanced Ref No: NISM/EV-DP/01 EV-DP ANALOGUE ADDRESSABLE DATE: NOV 2003 DUAL WAVELENGTH PHOTOELECTRIC SMOKE SENSOR PAGE: ISSUE: INSTRUCTION MANUAL Section 4 - INSTALLATION Routine Inspection In normal use, the EV-DP sensor will be installed at i) Ensure the sensor head is secure and undamaged. ceiling level.
  • Page 5: Section 6 - Specifications

    BS 5839 part 1. v) If the unit needs further cleaning, or is damaged or corroded, please return the complete sensor to Nittan (UK) Ltd. for service. Electromagnetic Compatibility (EMC) On a site where there is an unusually high level of potential electrical interference, e.g.
  • Page 6: Section 9 - Address Setting

    evolution-advanced Ref No: NISM/EV-DP/01 EV-DP ANALOGUE ADDRESSABLE DATE: NOV 2003 DUAL WAVELENGTH PHOTOELECTRIC SMOKE SENSOR PAGE: ISSUE: INSTRUCTION MANUAL Section 9 - ADDRESS SETTING • Insert sensor to be programmed into the base. • Press any key on the keypad to bring the programmer out of ‘Sleep’ mode, then enter the password (default is 1111), then press ‘OK’.
  • Page 7: Section 10 - Connections

    evolution-advanced Ref No: NISM/EV-DP/01 EV-DP ANALOGUE ADDRESSABLE DATE: NOV 2003 DUAL WAVELENGTH PHOTOELECTRIC SMOKE SENSOR PAGE: ISSUE: INSTRUCTION MANUAL Section 10 - CONNECTIONS RIL must be LED type Max. current through 3 = 3mA @ 24V d.c. Base Control STB-4-EV base STB-4SE-EV base Auxiliary terminal RIL current limited to 3mA.