Operating Instruction Thank you for purchasing this product. For optimum performance and safety, please read these instructions carefully before connecting, operating or adjusting this product. Please keep this manual for future reference. SURGE PROTECTION DEVICE RECOMMENDED This product contains sensitive electrical components that may be damaged by electrical spikes, surges, electric shock, lightning strikes, etc.
Operating Instruction 1. Features 4x HDMI Inputs which can be independently routed to HDMI Outputs. No switching delay or picture loss during transitions Supports resolution up to 4K@60HZ 4:4:4 Supports Video Wall up to 7 different modes with each monitor with 4K@60Hz 4:4:4 resolution.
Operating Instruction 3. Specifications Operating Temperature Range -5 to +40°C(23 to +104 °F) Storage Temperature Range -10 to +60°C(-14 to +140 °F) Operating Humidity Range 5 to 90 % RH (no condensation) Input Video Signal 0.5-1.0 volts p-p Input DDC Signal 5 volts p-p (TTL) Bandwidth 18Gbit/s...
Operating Instruction Rear Panel ① Audio In ② Audio Out ③ S/PDIF OUT ④ IR Ext ⑤ RS232 port ⑥ HDMI IN x4 ⑦ HDMI OUT x4 ⑧ Ethernet port ⑨ Power input 12V/3A 5. Wiring Diagram Seamless Matrix Mode...
Operating Instruction 6. Input / Output Channel Key Operation Channel Button Method 1. Directly press the number key, such as input channel 1, and select "1" to press (only OUT1-4 when the output port is selected, the input channel number will be valid) 2.
Operating Instruction Operation: press “2”, “1” and “3” in Output area + “2” in IN source area to complete the switch 3. Switch all output to input 4 source press “ Operation: 4” in Output area + “4” in IN area to complete the switch Main Menu Main menu is divided into 5 module, which are Output, Input, Preset, Config, Info.
Page 11
Operating Instruction 1)Source Any output can be switched to one input, or all outputs can be switched to the same input; The default 4x4 matrix is 4-way input and 4-way output one to one output. Operation: ① Select “Output” in the main menu and press “ENTER” ②...
Page 12
Operating Instruction ⑦ Select “On” or “Off”, press “ENTER” to complete the operation. The blue screen will be displayed after turning off the output. 3)Pattern Built-in image of a matrix can be showed onto the TV by Pattern, which is mainly used for testing in special occasions.
Page 13
Operating Instruction Operation: ① Select “Output” in the main menu and press “ENTER” ② Press “UP” or “DOWN” to select “ Output 1~4, all” ③ Click “ENTER” to enter the next sub-menu ④ Press “UP” or “DOWN” to select “Video” ⑤...
Page 14
Operating Instruction Operation: ① Select “Output” in the main menu and press “ENTER” ② Press “UP” or “DOWN” to select “ Output 1~4, all” ③ Click “ENTER” to enter the next sub-menu ④ Press “UP” or “DOWN” to select “Video” ⑤...
Page 15
Operating Instruction Operation: ① Select “Output” in the main menu and press “ENTER” ② Press “UP” or “DOWN” to select “ Output 1~4, all” ③ Click “ENTER” to enter the next sub-menu ④ Press “UP” or “DOWN” to select “Video” ⑤...
Page 16
Operating Instruction Operation: ① Select “Output” in the main menu and press “ENTER” ② Press “UP” or “DOWN” to select “ Output 1~4, all” ③ Click “ENTER” to enter the next sub-menu ④ Press “UP” or “DOWN” to select “Video” ⑤...
Page 17
Operating Instruction Remarks: A layer can select only one output, cannot select it repeatedly, otherwise it does not take effect. 10)Wall Wall is used to set the coordinate position of the TV. By default, it is in accordance with the matrix silkscreen making sequence.
Operating Instruction 11) Image Image is used to set the parameters of output image. There are 4 parameters: Brightness, Contrast, Staturation, Hue, Parameter Ranges from 0 to100 and it is 50 by default. Operation: ① Select “Output” in the main menu and press “ENTER” ②...
Page 19
Operating Instruction Operations: ① Select “Output” in the main menu and press “ENTER” ② Press “UP” or “DOWN” to select “ Output 1~4, all” ③ Click “ENTER” to enter the next sub-menu ④ Press “UP” or “DOWN” to select “Video” ⑤...
Operating Instruction 3)DEC onoff DEC onoff can implement the audio out switch. Click “On” to turn on the audio, click “Off” to turn off the audio. It is on by default. Operations: ① Select “Output” in the main menu and press “ENTER” ②...
Operating Instruction “Off” in “Power”. It is on by default. Operation: ① Select “Output” in the main menu and press “ENTER” ② Press “UP” or “DOWN” to select “ Output 1~4, all” ③ Click “ENTER” to enter the next sub-menu ④...
Page 22
Operating Instruction 1) Video Video can implement the on-off of input channel. All the outputs correspond to the input will have no image and audio when this input is set to “Off”. Pattern provides built-in pattern, the selected built-in pattern will replace the input source image. Operation: ①...
Page 23
Operating Instruction temporarily stored in the case of continuous power supply after access. Connect a new TV EDID will update. The default Modify is on. After copying the TV EDID, the audio parameter is automatically changed to LPCM2.0. If closed; The copied EDID does not modify the audio parameters. Default1 4K60 444-LPCM: 2.0-192Khz Default2...
Operating Instruction Preset Preset can save the current video, audio, EDID and system settings, supports 8 different scenes. Preset can be modified and called using WEB, commands and panel. The default preset is consistent with its factory settings. There are 4 options as follow: Clear: Remove the selected preset.
Page 25
Operating Instruction Demo operation: Timer can set the rotation time, the default is “Endless”, the minimum time is 3 seconds. Select indicates whether Select whether to perform the scenario in rotation. If this parameter is set to yes, the scenario will be played. If this parameter is not set to yes, the scenario will be skipped.
Operating Instruction Demo Config Config can set network, RS232, LCD, OSD, MENU, user EDID, system. Gray sections cannot be selected, a higher level is required to enable the function. The level are read-only and read-write. 1) Network Network can set DHCP, IP, Mask, Gateway, Port and Mac. The Mac address cannot be changed. The default IP address is 192.168.1.200 DHCP operation: ①...
Page 27
Operating Instruction ④ Press “UP” or “DOWN” to select baud rate “DHCP” ⑤ Press “UP” or “DOWN” to select “No” or “Yes” to complete the operation. IP/MASK/gateway Operation: ① Select “Config” in the main menu and press “ENTER” ② Press “UP” or “DOWN” to select “ network ” ③...
Page 28
Operating Instruction Operation of TCP/UDP port number change ① Select “Config” in the main menu and press “ENTER” ② Press “UP” or “DOWN” to select “ network ” ③ Click “ENTER” to enter the next sub-menu ④ Press “UP” or “DOWN” to select baud rate “Port” to enter the next sub-menu ⑤...
Page 29
Operating Instruction Bright 0 to 8 indicates the backlight level, and 0 indicates off. Timer can be set to 3 seconds ~ Endless. Operation: ① Select “Config” in the main menu and press “ENTER” ② Press “UP” or “DOWN” to select “ Bright ” ③...
Page 30
Operating Instruction Menu indicates that the LCD is mapped to the TV. INFO indicates the displayed time of audio and video information. When all options set to 0 seconds, the parameters will not display. By default, User and time are Endless, menu and INFO are30 seconds.
Page 31
Operating Instruction Operation: ① Select “Config” in the main menu and press “ENTER” ② Press “UP” or “DOWN” to select “ Menu ” ③ Click “ENTER” to enter the next sub-menu ④ Press “UP” or “DOWN” to select “Timer” and press “ENTER” ⑤...
Page 32
Operating Instruction Operation: ① Select “Config” in the main menu and press “ENTER” ② Press “UP” or “DOWN” to select “ User EDID ” ③ Click “ENTER” to enter the next sub-menu ④ Press “UP” or “DOWN” to select “User1” and press “ENTER” ⑤...
Page 33
Operating Instruction Operation: ① Select “Config” in the main menu and press “ENTER” ② Press “UP” or “DOWN” to select “ System ” ③ Click “ENTER” to enter the next sub-menu ④ Press “UP” or “DOWN” to select “Reboot” and press “ENTER” ⑤...
Operating Instruction ④ Press “UP” or “DOWN” to select “Factory” and press “ENTER” ⑤ Select “Simple” and press “ENTER” to enter the next sub-menu ⑥ Press “UP” or “DOWN” to select “Yes” to restore factory setting. Info Query device information, including input, output, system, and log. The information can only be queried and cannot be set or changed.
Operating Instruction When selecting Output,means Out1--out4 When selecting Input,means In1--In4 :Preset :(N/A) :Point to Point 9. Audio Extraction HDMI audio Default HDMI audio output support uncompressed audio PCM, LPCM2.0 digital audio DTS/Dolby5.1 channel. The maximum sampling rate support 192KHZ, and it supports audio format and channel are forced into LCPM2.0.
Operating Instruction *2: The EDID sampling rate is forced to be 48Khz by default. Other audio sampling rates can be supported only when the forced modification function is disabled. 1) Analog Audio HDMI 1~4 indicates that HDMI output audio select audio from other input signal sources ①...
Page 37
10.2 Comport setting: Choose correct COM port that connect to PC in parameter configuration area. Serial Port Default Settings Baud Rate 115200 bps(Default) Parity Bits None Data Bits Stop Bits 10.3 Enter Port Command in Send options. 10.4 Command List 1).All commands start with “#”...
Operating Instruction 11. Scene Instructions 11.1 Video Wall Mode Remarks: Parts of the scene require switching TV ports. For Example: Out2 and out3 need to be swapped when in mode W-2x1. W-2x2:2 Vertical x 2 Horizontal W-1x2:1 Vertical x 2 Horizontal W-1x2 1x2:1 Vertical x 2 Horizontal...
Page 39
Operating Instruction W-1x3: 1 Vertical x 3 Horizontal W-1x4: 1 Vertical x 4 Horizontal W-2x1:2 Vertical x 1 Horizontal W-2x1 W-2x1: 2 Vertical x 1 Horizontal...
Page 40
Operating Instruction W-3x1: 3 Vertical x 1 Horizontal W-4x1:4 Vertical x 1 horizontal...
Operating Instruction Changing coordinates only supports operation panel; Default wall coordinates output 1 (0,0) output 2 (1,0) output 3 (0,1) output 4 (1,1); Output 1 number of wall width=2 and height=2. Other outputs must be auto. If output 1 and output TV exchange with each other; Output 1 (1,0) output 2 (0,0) output 3 (0,1) output 4 (1,1);...
Operating Instruction 12. Web Control 12.1 Change IP address of PC Before configuring the device through the website, it is necessary to configure the IP address of the computer configured with the device (mainly to ensure that the computer and the device are set in the same network segment). 1).
Operating Instruction 3). Subnet mask set to 255.255.255.0 4). Gateway set to 192.168.1.1 Operating Instruction 12.2 Log in by browser Default IP address for log-in:192.168.1.200 Type in user name and password (default user and default password: admin) Note:suggest to use newer version of Google, Firefox, browser for better compatibility.
Operating Instruction 13.1 Status In the Status interface, you can only view information but cannot modify it 2) Input INFO displays the resolution, audio and HDCP information of the input signal source 3) Output EDID Info interface will display partial EDID information of TV 4) Device Info displays MCU version and web version 13.2 Input Menu...
Operating Instruction 5) USER EDID can save the EDID of Bin document to User1~4. Click Browse to find the route of EDID, select User1~4 and click upload to save it. 6) Copy EDID of sink to User1~4 13.3 Output Menu 1) Rename: Output name can be changed, double click output1~4 to modify 2) Video: Click the green button to enable or disable the video outputs.
Operating Instruction Audio Dec: Turn on/off audio separation, coaxial and analog on and off at the same time. 6) Dec Src: audio separation switching, click the drop-down list box to select hdMI1-4 and AUTO HDMI options. The options take effect automatically without confirmation. 7) Format: Output video format, the default is auto.
Operating Instruction 13.5 Preset Menu Preset can be used to call, save, clean and customize the scene name. 1) Seamless matrix can complete P2P, input1, input2, input3, input4. Click the drop-down box to select "Call", click "Save" to save the current scene, and click "Clear" to clear the scene to the default value. 2) Video wall can customize the new scene.
Operating Instruction 4) Scene can save and customize scene. There are 8 scenes. The default scene is the same as factory setting. 5) Rename can change the scene name. Double click to modify the name. 13.6 Advance 1) PIP mode switch. Click the button to enable or disable the mode. 2) Crop-X0 (Image cropping starting point of horizontal coordinates, range 0~6000) Crop-Y0 (Image cropping starting point of vertical coordinates, range 0~6000)
Operating Instruction 13.7 System 1) Network includes Mac address, IP, mask, gate, DHCP, TCP port. Mac address cannot be modified. IP address can modified in condition that HDCP is off and a highest level account is required. 2) Account Management can revise account. A high level account cannot be modified by a low level account which can modify the current login account only.
Operating Instruction 14.2 GUI Web Page Upgrade Open software UART_ISP_V1.6.exe in PC, select correct port, baud rate 115200, input F0 and select a program (xxx.HTML) in path, click update to complete upgrade.
Operating Instruction 15. Maintenance Clean this unit with a soft, dry cloth. Never use alcohol, paint thinner of benzine to clean this unit. 16. Product Service 1) Damage requiring service: The unit should be serviced by qualified service personnel if: (a) The DC power supply cord or AC adaptor has been damaged;...