EVAL-ADM2463EEBZ/EVAL-ADM2763EEBZ
IEC 61000-4-2 ELECTROSTATIC DISCHARGE
(ESD) PROTECTION
The EVAL-ADM2463EEBZ/EVAL-ADM2763EEBZ are tested
and verified to achieve protection against IEC 61000-4-2 ESD to
≥±12 kV (contact discharge) and ≥±15 kV (air discharge) on
the
ADM2463E
or
ADM2763E
The IEC 61000-4-2 ESD standard describes testing using two
coupling methods known as contact discharge and air discharge.
Contact discharge implies a direct contact between the discharge
Pin A, Pin B, Pin Y, and Pin Z.
User Guide
gun and the equipment under test (EUT). The
ADM2763E
is tested using both of these methods.
During testing, the
Pin Y, and Pin Z are subjected to at least 10 positive and 10
negative single discharges with a 1 sec interval between each
pulse. The highest specified IEC 61000-4-2 ESD test is Level 4,
which defines a contact discharge voltage of ±8 kV and an air
discharge voltage of ±15 kV.
Rev. 0 | Page 7 of 11
ADM2463E
ADM2463E
or
ADM2763E
Pin A, Pin B,
UG-1715