PROGRAMMING:
GT-DMB-N(-LVN) Entrance Station Addressing
Step 1:
Using the GT Support Tool for Windows, upload the program file to the GT-DMB-N(-LVN) with the
USB cable provided. Click
Step 2 :
While in standby mode, enter # plus the Admin ID code (default is
Step 3:
Use the up / down arrows and scroll to PROGRAMMING . Push the Bell button
enter programming mode. The amber LED will begin flashing, then remain steadily lit. Once lit, the
entry panel is in programming mode. The LCD will show "CONNECTING" while in programming
mode.
Step 4:
At a tenant station, push and release the TALK button or pick up the handset to establish
communication with the entrance station in programming mode.
Step 5:
Scroll to the station number to be programmed or manually enter the number on the keypad.
When the tenant station number is displayed, push and release the Bell button
address to the tenant station that is active. A blip tone will be heard.
Do not press and hold the Bell button as doing so will clear the memory for this number.
Step 6:
Turn off or hang up tenant station (GT-1A/GT-1C7/GT-1M3: Press TALK again,
GT-2C: Press OFF).
Step 7:
Repeat steps 4-6 for the remaining tenant stations.
Step 8:
To exit programming, press the "X" button twice on the panel to return to the main menu (the amber
LED will turn off). Scroll to QUIT and press the Bell button
Step 9:
Download the program file to the GT Support Tool from the GT-DMB-N(-LVN) with the USB cable
provided. Click
Step 10: Click
to save the file to the computer.
GT-MKB-N Video Guard Station Addressing
Step 1:
Using the GT Support Tool for Windows, upload the program file to the GT-MKB-N with the USB
cable provided. Click
Step 2:
While in standby mode, press Setting. Scroll down to
Zoom/Wide button.
Step 3:
Use the up/down arrows and scroll to PROGRAM MODE . Press the Zoom/Wide button. Enter
the passcode (*1111). Re-enter the passcode again.
Scroll to PROGRAMMING and select PROGRAMMING again from the next screen.
Step 4:
Step 5:
The screen will show CONNECTING . When the orange LED on the unit remains steadily lit, the
unit will be in programming mode.
Step 6:
At a tenant station, push and release the TALK button or pick up the handset to establish
communication with the GT-MKB-N in programming mode.
Step 7:
Scroll to the station number to be programmed or manually enter the number on the keypad.
When the tenant station number is displayed, push and release the Zoom/Wide button to assign
the address to the tenant station that is active. A blip tone will be heard.
Do not press and hold the Zoom/Wide button as doing so will clear the memory for this number.
Step 8:
Turn off or hang up tenant station (GT-1A/GT-1C7/GT-1M3: Press TALK again,
GT-2C: Press OFF).
Step 9:
Repeat steps 6-8 for the remaining tenant stations.
Step 10: To exit programming, press the SETTING button twice to return to the main menu. Scroll to
QUIT and press the Zoom/Wide button to return to standby. The system is now ready for use.
Step 11: Download the program file to the GT Support Tool from the GT-DMB-N with the USB cable
provided. Click
Step 12: Click
to save the file to the computer.
ADDRESSING TENANTS VIA HANDSHAKE METHOD (continued)
then select the station to upload to and click OK .
then select the station to download from and click OK .
then select the station to upload to and click OK .
then select the station to download from and click OK .
*
1111). Re-enter ID code.
. The system is now ready for use.
ADVANCED SETTINGS
twice to
to assign the
and press the
1
1
2
2
ABC
ABC
4
4
5
5
GHI
GHI
JKL
JKL
7
7
8
8
PQRS
PQRS
TUV
TUV
0
0
3
3
DEF
DEF
6
6
MNO
MNO
9
9
WXYZ
WXYZ
#
#
15

Advertisement

Table of Contents
loading

Table of Contents