Dehumidifying Operation; Adjusting Air Flow Direction; Timer Operation - Bosch ASI09DW40 Manual

Table of Contents

Advertisement

Available languages

Available languages

Dehumidifying operation

Ensure the unit is plugged in and power is
available. The OPERATION indicator on the
display panel of the indoor unit starts flashing.
1. Press the MODE button to select DRY mode.
2. Press the UP/DOWN buttons to set the
desired temperature. The temperature
can be set within a range of 17 C~ 30 C
O
in 1 C increments.
3
3. Press the ON/OFF button to start the air
2
2
conditioner.
ON/OFF
TEMP
NOTE
In the Dehumidifying mode, you can not switch the
1
MODE
SILENCE
fan speed. It has already been automatically controlled.
FP
FAN
SWING
SPEED
TIMER
DIRECT
ON

Adjusting air flow direction

TIMER
SLEEP
OFF
Use the SWING and DIRECT button to adjust
TURBO
LED
SELF
FOLLOW
the desired airflow direction.
CLEAN
ME
1. When push the DIRECT button, the horizontal
RESET
LOCK
louver changes 6 degree in angle for each
push.
2. When push the SWING button, the louver
will swing up and down automatically.
NOTE: When the louver swing or move to a
position which would affect the cooling
or heating effect of the air conditioner,
it would automatically change the
swing/moving direction.
O
O
9

Timer operation

Press the TIMER ON button can set the auto-on
time of the unit. Press the TIMER OFF button
can set the auto-off time of the unit.
To set the Auto-on time.
1. Press the TIMER ON button. The remote
controller shows TIMER ON, the last Auto-on
setting time and the signal "h" will be shown on
the LCD display area. Now it is ready to reset
the Auto-on time to START the operation.
2. Push the TIMER ON button again to set desired
Auto-on time. Each time you press the button,
ON/OFF
the time increases by half an hour between 0
TEMP
and 10 hours and by one hour between 10 and
24 hours.
MODE
SILENCE
FP
3. After setting the TIMER ON ,there will be a one
FAN
SWING
SPEED
second delay before the remote controller
transmits the signal to the air conditioner. Then,
1
TIMER
DIRECT
after approximately another 2 seconds, the
ON
signal "h" will disappear and the set temperature
TIMER
SLEEP
2
OFF
will re-appear on the LCD display window.
TURBO
LED
SELF
FOLLOW
CLEAN
ME
To set the Auto-off time.
LOCK
RESET
1. Press the TIMER OFF button. The remote
controller shows TIMER OFF, the last Auto-off
setting time and the signal "h" will be shown on
the LCD display area. Now it is ready to reset
the Auto-off time to stop the operation.
2. Push the TIMER OFF button again to set
desired Auto-off time. Each time you press the
button, the time increases by half an hour
between 0 and 10 hours and by one hour
between 10 and 24 hours.
3. After setting the TIMER OFF ,there will be a
one second delay before the remote controller
transmits the signal to the air conditioner. Then,
after approximately another 2 seconds, the
signal "h" will disappear and the set temperature
will re-appear on the LCD display window.
10

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents