Marantz PM6004/N1SG Service Manual page 25

Integrated amplifier
Table of Contents

Advertisement

When writing in the already written-in microcomputer (update)
Check Single Boot Mode in Address Mode.
Setting in Device Password
· Check Device is BLANK.
· Check Hex in input type.
· Type 0102030405060708 into Password.
· Type 0xFF00 into Password Character Number Address.
· Type 0xFF01 into Password Compare Start Address.
Setting in Object File Password
· Do not check BLANK password.
· Check Hex in Input Type.
· Type 0102030405060708 into Password.
· Type 0xFF00 into Password Character Number Address.
· Type 0xFF01 into Password Compare Start Address.
Click OK.