Verifying the Version

1.
Turn on the power.
The power LED lights up and the scene screen is displayed.
* The Power switch is on the right hand side, when you have the body stand up
and see it from the front.
2.
Press MENU (backside).
The MENU screen is displayed. When pressing MENU several times on
the MENU screen, the cursor on the screen moves up or down. Locate the
cursor (
) on the upper line.
3.
Press
or
to select Version.
The version information is displayed on the screen.
Data Backup and Restore
Operations
There are two types of user settings that can be backed up and restored:
system settings and scene settings.
• System Settings: Various settings for the unit itself
• Scene Settings: The settings for each part, settings that are common to all
parts, user settings stored the entire state of performance settings
including assignments for the controllers and MIDI control settings, etc.
* For detailed information about the System and Scene Settings, refer to the
Owner's Manual (p. 8).
Items Required
• USB memory device (Type-C)
Formatting a USB Memory Device
1.
Hold down MENU and turn on the power.
Continue to hold down MENU until the Roland logo disappears.
2.
Connect the USB memory device to the USB connector on the unit.
3.
Press
to display USB Memory Format and press MENU.
4.
To execute formatting, press
select NO.
Selecting YES displays a confirmation screen.
5.
Press MENU.
Executing... is displayed on the screen and the USB memory device is
formatted. When formatting is finished, Complete appears and then the
display returns to the USB Memory Format screen.
6.
Turn off the power and disconnect the USB memory device.
Backing Up System Settings
1.
Follow Formatting a USB Memory Device (p. 6) to format the USB
memory device.
2.
Hold down MENU and turn on the power.
Continue to hold down MENU until the Roland logo disappears.
3.
Connect the USB memory device to the USB connector on the unit.
4.
Press
or
to display System Backup and press MENU.
5.
Press
to select YES. To cancel it, press
6.
Enter the file name.
Press
or
to move the cursor, then press
characters. Use S1 to insert one character and S2 to delete it.
7.
Press MENU.
Write OK ? is displayed on the screen.
8.
To execute the backup operation, press
press
to select NO.
Writing... is displayed on the screen and the backup operation is
executed. When the operation is finished, Complete appears and then
the display returns to the System Backup screen.
9.
Turn off the power and disconnect the USB memory device.
6
to select YES. To cancel it, press
to select NO.
or
to input the
to select YES. To cancel it,
Restoring System Settings
1.
Hold down MENU and turn on the power.
Continue to hold down MENU until the Roland logo disappears.
2.
Connect the USB memory device containing the backed-up data to the
USB connector on the unit.
3.
Press
or
4.
Press
to select YES. To cancel it, press
5.
Press
,
,
MENU.
A confirmation screen is displayed.
6.
To execute the restore operation, press
press
to select NO.
Writing... is displayed on the screen and the restore operation is
executed. When the operation is finished, Complete appears and then
the display returns to the System Restore screen.
* If files could not be read in correctly, Read Error is displayed. Verify the
connection of the USB memory device, then carry out the restore operation
again. Also, if the backed-up data of the scene setting is selected at System
Restore, Read Error is displayed.
7.
Turn off the power and disconnect the USB memory device.
Backing Up Scene Settings
1.
Execute steps 1 through 3 of Backing Up System Settings (p. 6) just
described.
2.
Press
or
3.
Enter the file name.
Press
or
characters. Use S1 to insert one character and S2 to delete it.
4.
Press MENU.
Write OK ? is displayed on the screen.
5.
To execute the backup operation, press
press
to select NO.
Writing... is displayed on the screen and the backup operation is
to
executed. When the operation is finished, Complete appears and then
the display returns to the Scene Backup screen.
6.
Turn off the power and disconnect the USB memory device.
Restoring Scene Settings
1.
Hold down MENU and turn on the power.
Continue to hold down MENU until the Roland logo disappears.
2.
Connect the USB memory device containing the backed-up data to the
USB connector on the unit.
3.
Press
or
4.
Press
to select YES. To cancel it, press
5.
Press
,
,
MENU.
A confirmation screen is displayed.
6.
Press
.
Writing... is displayed on the screen and the restore operation is
executed. When the operation is finished, Complete appears and then
the display returns to the Scene Restore screen.
* If files could not be read in correctly, Read Error is displayed. Verify the
connection of the USB memory device, then carry out the restore operation
again. Also, if the backed-up data of the System setting is selected at Scene
Restore, Read Error is displayed.
7.
Turn off the power and disconnect the USB memory device.
to display System Restore and press MENU.
to select NO.
or
to select the backed-up file and press
to select YES. To cancel it,
to display Scene Backup and press MENU.
to move the cursor, then press
to select YES. To cancel it,
to display Scene Restore and press MENU.
to select NO.
or
to select the backed-up file and press
AE-30
or
to input the

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aerophone pro

Table of Contents