7. AD
7-1. Bite Sensor
This checks the operation of the Bite Sensor.
* Be sure to perform this test with the user's mouth piece.
fig.test7.eps
T-S
AD
07/14
1/62
Start Bite Adjust ?
**
Start Bite Adjust ? is displayed on the screen.
1.
Press the reed with your fingers.
fig.test7-12-e.eps
Press the reed to make the reed
Press the reed to make the reed
and mouthpiece stick each other.
and mouthpiece stick each other.
2.
In the state of step 1, press
* Do not release your fingers until Bite [ 0 -- 300] is displayed on the screen.
3.
Release your fingers.
fig.test7-13.eps
4.
Verify that the value displayed on the lower line of the screen is within
the range from 0 to 300 and press
Bite [650 -- 770] is displayed on the screen.
5.
Press the reed again and verify that the value displayed on the lower line
of the screen is within the range from 650 to 770.
In the same way as step 1, make the reed and mouthpiece stick each
other.
* If the value displayed on the screen is not within the range from 650 to 770 in
the state above, the adjustment may have failed in steps 1 and 2.
In this case, redo the procedure from step 1.
6.
Press
to advance to the next test.
7-2. Bender Control
This checks the operation of the bender (thumb lever).
fig.test7-2.eps
T-S
AD
07/14
5/62
Bend Value Check
***
Bend Value Check is displayed on the screen.
7.
Press
.
Bend [80 -- 98] is displayed on the screen.
8.
Flip the bender all the way to the front and verify that the value displayed
on the lower line of the screen is within the range from 80 to 98.
fig.test7-3.eps
10
.
.
9.
Release your finger and verify that the bender returns to the center
automatically and the value displayed on the lower line of the screen is
within the range from 110 to 140.
10. Press
.
Bend [152 -- 170] is displayed on the screen.
11. Flip the bender all the way to the back and verify that the value displayed
on the lower line of the screen is within the range from 152 to 170.
12. Release your finger and verify that the bender returns to the center
automatically and the value displayed on the lower line of the screen is
within the range from 110 to 140.
13. Press
to advance to the next test.
7-3. Pressure Sensor
This checks the operation of the Pressure Sensor.
fig.test7-5.eps
T-S
AD
07/14
8/62
Prss Value Check
0
Prss Value Check is displayed on the screen.
14. Press
.
Prss [200 -- 230] is displayed on the screen.
15. Press the thumb pad with strength so that the value displayed on the
lower line of the screen is within the range from 200 to 230, and then
press
.
fig.test7-6.eps
16. Release your finger.
The value displayed on the lower line of the screen becomes 0.
17. Press
to advance to the next test.
7-4. Motion Value Check
This checks the operation of the Motion Sensor.
fig.test7-7.eps
T-S
AD
07/14
11/62
Motion Value Check
*
Motion Value Check is displayed on the screen.
18. Press
.
Motion [ 127
] is displayed on the screen.
19. Place the unit horizontally.
The value displayed on the lower line of the screen becomes 127.
fig.test7-8.eps
20. Press
, and then place the unit vertically.
The value displayed on the lower line of the screen becomes 0.
21. Press
to advance to the next test.
AE-30