Installation Instructions
Cooktop and Cutout Dimensions
Cooktop and Cutout Dimensions Inches (mm)
A
Overall width of cooktop
B
Overall depth of cooktop
C
Height of chassis below top of counter (including height of conduit junction)
D
Width of chassis
E
Depth of chassis (including spacers)
F
Overall width of cutout
G
Overall depth of cutout
https://producthelp.fisherpaykel.com/us/Cook/Cooktops/Electric/Five_Burners/CE365DBX1/User_Guide_CE365DBX1/02_inst...
CE244C
CE365D
23 5⁄8" (600
35 7⁄16" (900
20 7⁄8" (530)
20 7⁄8" (530)
4 ¼ " (108)
4 ¼ " (108)
21 5⁄8" (550)
34 1⁄8" (866)
19 7⁄8" (505)
19 5⁄8" (498)
22 1⁄8" (562)
34 ¼ " (870)
20 1⁄16" (510)
20 1⁄16" (510)
Updated: Thu, 18 Aug 2022 14:48:43 GMT
Powered by
1

Advertisement

loading

Summary of Contents for Fisher & Paykel CE244C

  • Page 1 Installation Instructions Cooktop and Cutout Dimensions CE244C CE365D Cooktop and Cutout Dimensions Inches (mm) Overall width of cooktop 23 5⁄8” (600 35 7⁄16” (900 Overall depth of cooktop 20 7⁄8” (530) 20 7⁄8” (530) Height of chassis below top of counter (including height of conduit junction) 4 ¼...
  • Page 2 CE244C CE365D Cooktop and Cutout Dimensions Inches (mm) min. 1 3⁄16” min. 1 3⁄16” Thickness of countertop* (30)-max. 1 (30)-max. 1 (to enable the cooktop to be fastened with the supplied clamps) 9⁄16” (40) 9⁄16” (40) * If the countertop is thicker than 1 9⁄16” (40 mm), recess its underside to within the thickness range ‘H’.
  • Page 3 CE244C CE365D Clearance and Cabinetry Dimensions Inches (mm) Front edge of counter Minimum clearance from countertop to: 18” (457) 18” (457) Overhead cabinet not directly above the cooktop Minimum distance between cabinets either side of the cooktop 36” (915) 36” (915) Maximum depth of overhead cabinetry 13”...
  • Page 4 Fig. 2 Minimum clearances and Fig. 1 Minimum clearances and ventilation ventilation requirements - drawer or other requirements - oven installed below cooktop obstruction below Before you Install the Cooktop, Make Sure: • The countertop is square and level, and no structural members interfere with space requirements the countertop is made of a heat-resistant material.
  • Page 5 • Electrical installation must be carried out only by a licensed electrician. • The cooktop MUST be connected to the proper electrical voltage and frequency as specified: Model Rated Power Required Power Supply CE244C 5.9kW (4.4kW) 240V~,25A, 60Hz (208V~, 21.3A, 60Hz) CE365D 8.4kW (6.5kW) 240V~,35A, 60Hz (208V~, 30.3A, 60Hz)
  • Page 6 Connecting the Cooktop to the Power Supply • The nameplate label is located on the underside of the cooktop, on the right hand side. See Fig. 5 below. • If the appliance is to be completely enclosed in a cabinet, feed the appliance cable through the opening in the cabinet.
  • Page 7 Location o Fig. 3 Fig. 4 Fastening the Cooktop to the Counter 1. Turn the cooktop upside down and place it on a soft surface. 2. Spread the seal around the edges of the cooktop with the adhesive side facing down, as shown in Figs. 6 and 7.
  • Page 8: Final Checklist

    Fig. 6 Preparing the cooktop before installation Fig. 7 Fastening the cooktop to the counter Final Checklist To be Completed by the Installer • Is the cooktop grounded? • Check that the connection through conduit is not accessible via cupboard doors or drawers. Is the cooktop clamped down securely? •...