External event counter
Hide thumbs Also See for 78K0S/K 1+ Series:
Table of Contents

Advertisement

CHAPTER 5 OPERATION CHECK USING SYSTEM SIMULATOR SM+
(3) Click the [TI000] button in the I/O panel window, during program execution.
The waveform of TI000 is as follows when the [TI000] button is clicked.
Goes from high level to low level by clicking
the [TI000] button.
Check that, by clicking the [TI000] button 10 times, the valid edge (falling edge) is detected for 10 times
the [LED] output in the I/O panel window and the LED waveform displayed in the timing chart window are
reversed.
I/O Panel Window
The LED output is reversed
every 10 times the [TI000]
button is clicked.
Note With an actual device, only the first LED output reversal takes place when the valid edge (falling edge)
of the TI000 pin is detected for 11 times. (The second and following LED output reversals take place
when the valid edge is detected for 10 times.)
Timing Chart Window
10 ms
LED output reversal
The number of times the [TI000]
button is clicked: 10
Application Note U18888EJ1V0AN
Goes from low level to high
level after 10 ms elapse.
Timing Chart Window
LED output reversal
The number of times the [TI000]
button is clicked: 10
Note
, and