Electronic Control System Installation And Use; Installation; Use Of Electronic Control System - Teba therm T-30 Installation Manual

Boiler with solid fuel
Table of Contents

Advertisement

Note: The amount of hot water to be supplied from our boiler must not
exceed 6 lt per minute. The temperature ratio is 75% of the boiler
temperature. The boiler water temperature should not be lower than 55° C.

5. ELECTRONIC CONTROL SYSTEM INSTALLATION AND USE

5.1 INSTALLATION

1- The electrical and sensor sockets on the upper part of the solid fuel floor
heater are attached to the sockets at the bottom of our electronic control
system as shown in Figure-6.
2- The feet of our electronic control system should be put into the holes at
the top of the boiler.
Caution: During the installation, the electronic sensor or the connection
cables should not be removed. The power should be 230 V and 50 Hz.

5.2 USE OF ELECTRONIC CONTROL SYSTEM

1-) When the electronic control system is installed and the power cable is
plugged, the temperature and the circulation pump are visible on the display
of the electronic control system.
2-) When pressing one time the "MENU" button on the electronic control
system, the fan section is displayed and the operating temperature lowest
limit value of the fan motor starts to flash. Press the (+) and (-) buttons on
the right side of the control system to enter the temperature value that you
want the fan motor to start with. When the boiler temperature rises above
this value, the fan activates automatically and starts working. When the
boiler temperature falls below the set value, the fan motor automatically
deactivates and the fan motor stops.
3-) When the "MENU" key on the electric control system is pressed twice,
the fan section comes to the screen and the highest limit value of the
operating temperature of the fan motor starts flashing. Press the (+) and (-)
7