While you are installing your product please check the fire and chimney
regulations on force in your country. . Minimum saftey distances specified
below must be complied with;
A
from the rear wall 25 cm
B
from the side wall 15 cm
C
from the radiation area (front side of the stove) 80 cm
There mustn't be any combustible material within 80 cm (80cm) from the
door of the stove. This distance would be 40cm if, a fire protection panel is
placed between the stoves door and the material.
If the stove is to be placed on a fire sensitive floor, fire protective base like
marble, glass or metal should be used.
Minimum dimensions of a base is specified below;
D
50 cm (from the door to edge of the base)
E
30 cm (from the inner edge of the door to edge of the base).