Advertisement

Available languages

Available languages

ENGLISH, FRANCAIS
This water heater design has been certified by the Canadian
Standards Association for installation in recreation vehicles. This
water heater is not for use in marine applications.
SERVICE CALLS & QUESTIONS
Location and phone numbers of qualified Service Centers can
be found at our website http:/www.atwoodmobile.com or call
815-877-5700 to have a Service Center List mailed.
SAFETY ALERT SYMBOLS
Safety Symbols alerting you to potential personal safety hazards.
Obey all safety messages following these symbols.
WARNING
avoid possible
injury or death
Installation and service must be performed by a qualified Service
Technician, Service Center, OEM or Gas Supplier.
FIRE OR EXPLOSION
• If the information in this manual is not followed
exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
➤ Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Evacuate
persons from vehicle.
ALL
• Shut off gas supply at gas container or source.
touch any electrical switch, or use any phone or
DO NOT
radio in vehicle.
start vehicle's engine or electric generator.
DO NOT
• Contact nearest gas supplier or qualified Service Technician
for repairs.
• If you cannot reach a gas supplier or qualified Service
Technician, contact the nearest fire department.
turn on gas supply until gas leak(s) has been
DO NOT
repaired.
(et Canada)
CAUTION
avoid possible
injury and/or property damage
WARNING
•Installation •Operation •Maintenance
WATER HEATER
MODEL IDENTIFICATION
DIMENSIONS
................................................................
WEIGHT
..................................................................
SAFETY INFORMATION
Water Heater
GENERAL INSTALLATION
Electronic Ignition wiring installation
Pilot Relight wiring installation
Heat Exchanger
Combination Gas/Electric
Water Heater
PILOT OPERATION
Electronic Ignition
Pilot Relight
Combination Gas/Electric
..........................................................
Water Heater
MAINTENANCE
Electronic Ignition
Electric
1-11 ............................................................................
FIGURES
........................................................................
WIRING DIAGRAMS
..................................................................
PART IDENTIFICATION
..............................................................
Water Heater
WARRANTY
EXPLANATION OF MODEL NUMBER
G
C
H
6
AA - 8
- IF YOUR MODEL NUMBER IS NOT LISTED-
Older revision numbers may be 3, 4, 6, 7, 8 or 9 (_ _ _ _ _ - X _)
Regardless of your revision number the current instructions are still generally
applicable to your unit. If you have questions contact your dealer, an Atwood
Service Center or the Atwood Service Department.
MODEL NUMBER CLARIFICATION
TYPE
4
GAL
Pilot Ignition
G4-7
GC6AA-8
Electronic Ignition
GC6AA-9E
Pilot Relight
Heat Exchange
Electronic Ignition
Combination Gas/Electric
DIMENSIONS
ALL MODEL
WIDTH
HEIGHT
6
16˝
12.5˝
GALLON
10
16˝
15.5˝
GALLON
1
MPD 93756
L.P. GAS
WATER HEATER
4 - 6 - 10 GALLON
Effective 4/02/02
............................................
..........................................................
..............................................
......................................................
(
)
EXAMPLE
E/P
Electronic Ignition or Pilot Relight
Revision (
)
NUMBER
Heating Element (
SCREW
4 - 6 - 10 gallon capacity
Engine Heat Exchange
Combination Gas and AC Electric
Gas (
)
PROPANE
6
GAL
G6A-7
GC6AA-8P
G10-2
GH6-7
G10-2P
G6A-8E
GCH6A-9E
G10-3E
GH6-8E
GC10A-3E
P
# -
IN MODEL
SEE MODEL CLARIFICATION ABOVE
H
# -
IN MODEL
SEE MODEL CLARIFICATION ABOVE
E
# -
IN MODEL
SEE MODEL CLARIFICATION ABOVE
C
# -
IN MODEL
SEE MODEL CLARIFICATION ABOVE
SHIPPING WT.
6
GALLON
10
GALLON
1
1
1
2-4
2-3
3-4
4-5
6
7
8-9
16
-
-
)
IN OR BOLT
ON
10
GAL
GC10A-2
GC10A-2P
GCH10A-3E
GH10-3E
25 lbs
32 lbs

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the G4-7 and is the answer not in the manual?

Questions and answers

Robert Gardner Kowis
May 21, 2025

I have a Atwood 10 gal water heater Model G10-3E. The burner sometimes doesn't want to light, not sure if it would be the gas valve or the circuit board? At times I will see a small flame in the burn chamber and then a little flame at the air vent, Could you please guide me as to my problem and maybe how to troubleshoot it. Not sure what roll the circuit board and the gas valve do?

1 comments:
Mr. Anderson
May 24, 2025

When the burner does not light and there is a small flame in the burn chamber on an Atwood G10-3E water heater, follow these troubleshooting steps:

1. Check for gas line issues: Look for oil or moisture buildup in the gas line, which can block or restrict gas flow. Moisture can freeze and partially block the line. Make sure gas pressure is consistent to all appliances.

2. Inspect the gas regulator: Verify that the regulator is providing steady pressure. Intermittent pressure can cause ignition problems.

3. Check the main burner flame: It should be mostly blue with a small amount of yellow and burn quietly. If not:
- Adjust gas pressure to 11˝ W.C.
- Ensure the air shutter on the burner is 1/4 open.
- Confirm the flame spreader is square to the end of the burner.

4. Verify burner alignment: Ensure the manifold and burner tube are aligned. Rotate the gas valve and/or orifice holder so gas flows down the center of the burner tube.

5. Inspect the circuit board: Only check the circuit board after other steps. Make sure it is clean and dry before considering replacement.

Most ignition issues can be resolved by cleaning components or adjusting settings without replacing the circuit board.

This answer is automatically generated

Summary of Contents for Atwood G4-7

  • Page 1 ➤ Do not store or use gasoline or other flammable vapors and Regardless of your revision number the current instructions are still generally applicable to your unit. If you have questions contact your dealer, an Atwood liquids in the vicinity of this or any other appliance.
  • Page 2: Critical Installation Warnings

    • For an external electrical source, ground this unit in accordance with CAUTION National Electrical Code ANSI/NFPA70. PRODUCT DAMAGE Your Atwood gas water heater is now ready for operation. Continue to HOW TO OPERATE YOUR WATER HEATER. • Do not pull on main burner tube ( 9-C).
  • Page 3 For HEAT EXCHANGE continue — CONSUMER SAFETY WARNINGS 1. Push 5/8˝ dia. 2 or 3 coolant system hose with SAE 053 A Type “E”clamp attached ( 6-E) onto heat exchange tube as far as possi- WARNING ble ( 6-B). EXPLOSION OR FIRE 2.
  • Page 4: Maintenance And Care Instructions

    The use of manufacturer’s aftermarket heating element devices may 2. Slide air shutter ( 9-B) to right until some yellow appears in also result in damage to components or water heater. Atwood’s written main burner flame. warranty states - “failure or damage resulting from any alteration to 3.
  • Page 5 Remove air shutter screw ( 9-A) and slide air shutter ( 9-B) The Atwood water heater is designed with an internal air gap at the down burner tube. top of the tank to reduce the possibility of weeping and dripping. In b.
  • Page 6 6 GAL SHOWN 6 GAL SHOWN 6 GALLON 10 GALLON...
  • Page 7: Wiring Diagrams

    WIRING DIAGRAMS Dotted lines are wired by customer Gas Solenoid Non-Ignition Valves Light ( 4 ) ( 6 ) Switch Thermal Cut-Off Remote 12 volt DC BLUE Switch BROWN BROWN BROWN ( 3 ) ( 2 ) Fixed Temperature Control Thermostat REMOTE SWITCH SPARK IGNITION...
  • Page 8 PART IDENTIFICATION IDENTIFICATION DES PIÈCES WATER HEATER CHAUFFE-EAU PILOT RELIGHT RALLUMAGE DE VEILLEUSE ITEM 6 GALLON 10 GALLON VEILLEUSE D'ALLUMAGE PILOT IGNITION REFERENCE 22 LITRES 38 LITRES ✗ ✗ Tank Réservoir 90960 90960 Flue Box Assembly Cheminée complète 91857 91857 Drain Plug Bouchon de vidange (montré...
  • Page 9 PART IDENTIFICATION IDENTIFICATION DES PIÈCES SPARK IGNITION ALLUMAGE ÉLECTRONIQUE ITEM 6 GALLON 10 GALLON SPARK IGNITION ALLUMAGE ÉLECTRONIQUE REFERENCE 22 LITRES 38 LITRES ✗ ✗ Tank Réservoir 90960 90960 Flue Box Assembly Cheminée complète 91857 91857 Drain Plug Bouchon de vidange (montré...
  • Page 10 1. For a period of two years from the date of purchase, Atwood will 8. Damage or failure resulting from misuse (including failure to seek proper...
  • Page 11 à proximité de cet appareil ou d'autres appareils. généralement valables pour votre unité. Si vous avez des questions, contacter votre distributeur, un centre d'entretien Atwood ou le service à la clientèle QUE FAIRE SI VOUS SENTEZ DU GAZ? d'Atwood.
  • Page 12 INCENDIE ET/OU EXPLOSION MPD 93948). Consult your Field Auditor, Account Manager, or the Atwood Service Department if you have additional questions. • NE PAS utiliser d'allumettes, de bougies ou toute autre source d'al- lumage lorsque vous contrôlez la présence éventuelle de fuites.
  • Page 13 Le fil vert sur la borne négative de la batterie. d. Le fil marron du chauffe-eau sur la borne (3) de l'interrupteur. Votre chauffe-eau à gaz Atwood est maintenant prêt à l'utilisation. e. La borne 2 de l'interrupteur sur la borne à batterie positive.
  • Page 14: Instructions Pour L'entretien

    Si des problèmes persist- 4. Pour éteindre complètement l'unité ou pour toute réparation, fermer ent, contacter un centre de réparation agréé Atwood ou le centre de le robinet de contrôle du gaz (FIG 7-B or FIG 8-B) (position éteinte réparation Atwood.
  • Page 15 La tamination – s'il est propre, replacer l'orifice de la veilleuse. garantie écrite Atwood stipule que – la responsabilité d'un mauvais fonctionnement ou de dommages causés par une modification du COMMENT NETTOYER LES MODELES A ALLUMAGE ELECTRONIQUE chauffe-eau revient au propriétaire.
  • Page 16 à l'intérieur du système fermé d'un véhicule de plaisance. réparation. Le chauffe-eau Atwood a été conçu avec un écart d'air en haut du réservoir afin de réduire la possibilité d'écoulement ou de gouttes qui s'échappent. Avec le temps, l'expansion de l'eau absorbera cet air.
  • Page 17 8. Les dégâts ou les défaillances résultant d'une mauvaise utilisation (y 1. Pendant une période deux 2 ans à compter de la date d'achat, Atwood compris le manque de réparation appropriée), une mauvaise applica- remplacera le chauffe-eau complet si le réservoir interne fuit à...

Table of Contents