Atwood G4-7 Installation, Operation And Maintenance Instructions

Hide thumbs Also See for G4-7:

Advertisement

http://waterheatertimer.org/Atwood-water-heater-resources.html
ENGLISH, FRANCAIS
This water heater design has been certified by the Canadian
Standards Association for installation in recreation vehicles. This
water heater is not for use in marine applications.
SERVICE CALLS & QUESTIONS
Location and phone numbers of qualified Service Centers can
be found at our website http:/www.atwoodmobile.com or call
574-264-2131 to have a Service Center List mailed.
SAFETY ALERT SYMBOLS
Safety Symbols alerting you to potential personal safety hazards.
Obey all safety messages following these symbols.
WARNING
avoid possible
injury or death
Installation and service must be performed by a qualified Service
Technician, Service Center, OEM or Gas Supplier.
FIRE OR EXPLOSION
• If the information in this manual is not followed
exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
➤ Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Evacuate
persons from vehicle.
ALL
• Shut off gas supply at gas container or source.
touch any electrical switch, or use any phone or
DO NOT
radio in vehicle.
start vehicle's engine or electric generator.
DO NOT
• Contact nearest gas supplier or qualified Service Technician
for repairs.
• If you cannot reach a gas supplier or qualified Service
Technician, contact the nearest fire department.
turn on gas supply until gas leak(s) has been
DO NOT
repaired.
9
(et Canada)
CAUTION
avoid possible
injury and/or property damage
WARNING
LITERATURE NUMBER
•Installation •Operation •Maintenance
WATER HEATER
MODEL IDENTIFICATION
..........................................................
DIMENSIONS
................................................................
WEIGHT
..................................................................
SAFETY INFORMATION
Water Heater
GENERAL INSTALLATION
Electronic Ignition wiring installation
Pilot Relight wiring installation
Heat Exchanger
Combination Gas/Electric
Water Heater
PILOT OPERATION
Electronic Ignition
Pilot Relight
Combination Gas/Electric
..........................................................
Water Heater
MAINTENANCE
Electronic Ignition
Electric
1-11 ............................................................................
FIGURES
........................................................................
WIRING DIAGRAMS
..................................................................
PART IDENTIFICATION
..............................................................
Water Heater
WARRANTY
EXPLANATION OF MODEL NUMBER
G
C
H
6
AA - 8
- IF YOUR MODEL NUMBER IS NOT LISTED-
Older revision numbers may be 3, 4, 6, 7, 8 or 9 (_ _ _ _ _ - X _)
Regardless of your revision number the current instructions are still generally
applicable to your unit. If you have questions contact your dealer, an Atwood
Service Center or the Atwood Service Department.
MODEL NUMBER CLARIFICATION
TYPE
4 GAL
Pilot Ignition
G4-7
GC6AA-8
Electronic Ignition
G6A-8E
GC6AA-9E
Pilot Relight
P
Heat Exchange
H
Electronic Ignition
E
Combination Gas/Electric
C
DIMENSIONS
ALL MODEL
WIDTH
HEIGHT
6
16˝
12.5˝
GALLON
10
16˝
15.5˝
GALLON
1
MPD 93756
L.P. GAS
WATER HEATER
4 - 6 - 10 GALLON
Effective 11/19/07
............................................
..............................................
......................................................
(
)
EXAMPLE
E/P
Electronic Ignition or Pilot Relight
Revision (
)
NUMBER
Heating Element (
-
SCREW
IN OR BOLT
4 - 6 - 10 gallon capacity
Engine Heat Exchange
Combination Gas and AC Electric
Gas (
)
PROPANE
6 GAL
10 GAL
G6A-7
GC6AA-8P
G10-2
GH6-7
G10-2P
GCH6A-9E
G10-3E
GH6-8E
GC10A-3E
# -
IN MODEL
SEE MODEL CLARIFICATION ABOVE
# -
IN MODEL
SEE MODEL CLARIFICATION ABOVE
# -
IN MODEL
SEE MODEL CLARIFICATION ABOVE
# -
IN MODEL
SEE MODEL CLARIFICATION ABOVE
SHIPPING WT.
6
GALLON
10
GALLON
1
1
1
2-4
2-3
3-4
4-5
6
7
8-9
16
-
)
ON
GC10A-2
GC10A-2P
GCH10A-3E
GH10-3E
25 lbs
32 lbs

Advertisement

Table of Contents
loading

Summary of Contents for Atwood G4-7

  • Page 1 Regardless of your revision number the current instructions are still generally ➤ Do not store or use gasoline or other flammable vapors and applicable to your unit. If you have questions contact your dealer, an Atwood liquids in the vicinity of this or any other appliance.
  • Page 2: Critical Installation Warnings

    WARNING to MPD 93948). Consult your Field Auditor, Account Manager, or the SCALDING INJURY Atwood Service Department if you have additional questions. Valve is not serviceable, it must be replaced. • 1. Locate water heater on floor of coach before erecting side walls.
  • Page 3 (6) on indicator light of switch b. terminal (4) on indicator light of switch to negative battery terminal Your Atwood gas water heater is now ready for operation. Continue to c. green lead to negative battery terminal HOW TO OPERATE YOUR WATER HEATER.
  • Page 4: Maintenance And Care Instructions

    OFF position for at least 30 seconds, then turn to ON position. should activate, the water heater will not operate. Before replacing 6. If a lockout condition persists contact an Atwood Service Center. the fuse, check for a short external to the board. Once the short is &...
  • Page 5 Pressure Temperature Relief Valve will sometimes drip. The c. Vacuum burner where it enters combustion tube. Atwood water heater tank is designed with an internal air gap at the d. Return air shutter to original position and replace screw.
  • Page 6 6 GAL SHOWN 6 GAL SHOWN 6 GALLON 10 GALLON...
  • Page 7: Wiring Diagrams

    WIRING DIAGRAMS Dotted lines are wired by customer Gas Solenoid Non-Ignition Valves Light ( 4 ) ( 6 ) Switch Thermal Cut-Off Remote 12 volt DC BLUE Switch BROWN BROWN BROWN ( 3 ) ( 2 ) Fixed Temperature Control Thermostat REMOTE SWITCH GREEN...
  • Page 8: Part Identification

    PART IDENTIFICATION IDENTIFICATION DES PIÈCES WATER HEATER CHAUFFE-EAU PILOT RELIGHT RALLUMAGE DE VEILLEUSE ITEM 6 GALLON 10 GALLON ALLUMAGE DE VEILLEUSE PILOT IGNITION REFERENCE 22 LITRES 38 LITRES ✗ ✗ Tank Réservoir 90960 90960 Flue Box Assembly Boîtier du conduit 91857 91857 Drain Plug...
  • Page 9 7. The warranty period on replacement parts (or water heater) is the unused portion of the original warranty period or ninety (90) days, 1. For a period of two years from the date of purchase, Atwood will whichever is greater.

Table of Contents