Atwood MPD 93755 Installation Instructions Manual

4/6/10 gallon l.p. gas water heater
Hide thumbs Also See for MPD 93755:

Advertisement

ENGLISH, FRANCAIS
This water heater design has been certified by the Canadian
Standards Association for installation in recreation vehicles. This
water heater is not for use in marine applications.
SERVICE CALLS & QUESTIONS
Location and phone numbers of qualified Service Centers can
be found at our website http:/www.atwoodmobile.com or call
815-877-5700 to have a Service Center List mailed.
SAFETY ALERT SYMBOLS
Safety Symbols alerting you to potential personal safety hazards.
Obey all safety messages following these symbols.
WARNING
avoid possible
injury or death
Installation and service must be performed by a qualified Service
Technician, Service Center, OEM or Gas Supplier.
FIRE OR EXPLOSION
• If the information in this manual is not followed
exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

• Evacuate
persons from vehicle.
ALL
• Shut off gas supply at gas container or source.
touch any electrical switch, or use any phone or
DO NOT
radio in vehicle.
start vehicle's engine or electric generator.
DO NOT
• Contact nearest gas supplier or qualified Service Technician
for repairs.
• If you cannot reach a gas supplier or qualified Service
Technician, contact the nearest fire department.
turn on gas supply until gas leak(s) has been
DO NOT
repaired.
(et Canada)
CAUTION
avoid possible
injury and/or property damage
WARNING
LITERATURE NUMBER
•Installation •Operation •Maintenance
WATER HEATER
MODEL IDENTIFICATION

DIMENSIONS

................................................................
WEIGHT
..................................................................
SAFETY INFORMATION
Water Heater
Cutout Chart
Pressure - Temperature Relief Valve
..............................................................
................................................................
1-12 ..........................................................................
FIGURES
....................................................................
..............................................................
Water Heater
WARRANTY
EXPLANATION OF MODEL NUMBER
G
C
H
6
AA - 10
- IF YOUR MODEL NUMBER IS NOT LISTED-
Older revision numbers may be 3, 4, 6, 7, 8 or 9 (_ _ _ _ _ - X _)
Regardless of your revision number the current instructions are still generally
applicable to your unit. If you have questions contact your dealer, an Atwood
Service Center or the Atwood Service Department.

MODEL NUMBER CLARIFICATION

TYPE
4
GAL
Pilot Ignition
G4-7
GC6AA-8
Electronic Ignition
GC6AA-10E
Pilot Relight
Heat Exchange
Electronic Ignition
Combination Gas/Electric
DIMENSIONS
ALL MODEL
WIDTH
HEIGHT
6
16˝
12.5˝
GALLON
10
16˝
15.5˝
GALLON
1
MPD 93755
L.P. GAS
WATER HEATER
4 - 6 - 10 GALLON
Models 4-E & 10-E
Effective 10/29/02
............................................
..........................................................
..............................................
..................................................
..................................................
....................................................
......................................................
..................................................
(
)
EXAMPLE
E/P
Electronic Ignition or Pilot Relight
Revision (
)
NUMBER
Heating Element (
SCREW
4 - 6 - 10 gallon capacity
Engine Heat Exchange
Combination Gas and AC Electric
Gas (
)
PROPANE
6
GAL
G6A-7
GC6AA-8P
G10-2
GH6-7
G10-2P
G6A-8E
GCH6A-10E
G10-3E
GH6-8E
GC10A-4E
P
# -
IN MODEL
SEE MODEL CLARIFICATION ABOVE
H
# -
IN MODEL
SEE MODEL CLARIFICATION ABOVE
E
# -
IN MODEL
SEE MODEL CLARIFICATION ABOVE
C
# -
IN MODEL
SEE MODEL CLARIFICATION ABOVE
SHIPPING WT.
6
GALLON
10
GALLON
1
1
1
2-4
2-3
3
3-4
4-5
5
5
5
5
6-7
8
16
-
-
)
IN OR BOLT
ON
10
GAL
GC10A-2
GC10A-2P
GCH10A-4E
GH10-3E
25 lbs
32 lbs

Advertisement

Table of Contents
loading

Summary of Contents for Atwood MPD 93755

  • Page 1 Do not store or use gasoline or other flammable vapors and Regardless of your revision number the current instructions are still generally applicable to your unit. If you have questions contact your dealer, an Atwood liquids in the vicinity of this or any other appliance.
  • Page 2: General Installation

    2) hot water outlet female Flush Mount (MPD 93948) installations. Consult with your Field and cold water inlet female and 3/8˝ flared LP gas line to the water Auditor, Account Manager, or the Atwood Service Department if you heater ( have additional questions.
  • Page 3 • For an external electrical source, ground this unit in accordance with National Electrical Code ANSI/NFPA70. • Do not operate without water in tank. Your ATWOOD PILOT GAS WATER HEATER is now ready for operation. Continue to HOW TO OPERATE YOUR WATER HEATER PILOT OPERATION 1.
  • Page 4 The use of manufacturer’s aftermarket heating element devices may 2. If remote switch light stays on longer than 15 seconds, place also result in damage to components or water heater. Atwood’s written remote switch in OFF position and wait 5 minutes.
  • Page 5 These are indications of an obstruction in burner tube ( system of a recreation vehicle. 4-C). Inspect and clean on a regular basis. The Atwood water heater is designed with an internal air gap at the a. Remove air shutter screw ( 4-A) and slide air shutter ( 4-B) top of the tank to reduce the possibility of weeping and dripping.
  • Page 6 STRAIGHT SECTION VIEW Hot Water Outlet Cold Water Inlet From the Pump WHITE RODGERS ROBERTSHAW...
  • Page 7 –...
  • Page 8 PART IDENTIFICATION / IDENTIFICATION DES PIÈCES SPARK IGNITION / HEAT EXCHANGE PILOT IGNITION / PILOT RELIGHT COMBINATION GAS/ELECTRIC ITEM GALLON GALLON PILOT IGNITION VEILLEUSE D'ALLUMAGE REFERENCE LITRES LITRES Tank Réservoir 90960 90960 Flue Box Assembly Cheminée complète 91857 91857 Drain Plug Bouchon de vidange (montré...

This manual is also suitable for:

4-e10-e

Table of Contents