11. DISASSEMBLING THE BODY

11.1. EXTRACTING THE DRIP TRAY / USED CAPSULE TRAY AND THE WATER TANK ASSY

A

11.2. DISASSEMBLING THE SIDE PANELS AND THE TOP COVER

A
B
Note
While reassembling, tighten the screws with a torque of 1.6 ± 0.2 Nm.
Rel. 0.00 / February 2020
B
Figure A: after having removed
the power cable from the socket,
remove the DRIP TRAY / USED
CAPSULE TRAY.
Figure B: pull the WATER TANK
ASSY upwards to extract it from
its seat.
Figure
A:
remove
HANDLE CAPS of the capsule lo-
ading lever (one on each side).
L
Figure B: unscrew the two un-
derlying HANDLE SCREWS (one
on each side) and remove the
capsule loading lever.
B