Viper AS4325B Instructions For Use Manual page 15

Hide thumbs Also See for AS4325B:
Table of Contents

Advertisement

INSTRUCTION FOR USE
Battery installation
3.
Open the recovery tank cover (5, Figure 1) and check that the recovery tank (9, Figure 1) is empty;
otherwise empty it with the drain hose. (4, Figure 1)
4.
Close the recovery tank cover (5, Figure 1).
5.
Move the recovery tank kit (A, Figure 3) carefully.
6.
The machine is supplied with cables suitable to install 2X12V batteries. Carefully put the batteries into
the compartment, then install them correctly.
7.
Route and install the battery cable as shown in (Figure3), then carefully tighten the nut on each battery
terminal.
8.
Place the protection cap on each terminal, then connect the battery connector (B, Figure 3).
9.
Carefully put it back the recovery tank kit (A, Figure 3).
Battery charging
10. Charge the batteries. (See procedures in maintenance chapter).
CAUTION!
Cut off all the power of the machine before performing the following procedure!
Battery charger setting
11. Remove the screws (A, B, C, Figure 4.1).
12. Open the charger and find the sw1 (D, Figure 4.1).
13. Set the switches as the table of Figure 4.1.
14. Install the screws (A, B, C, Figure 4.1) after setting complete.
A
C
B
SW1
ON
OFF
DP1 DP2
DP1 DP2
CHARGING CURVE
ON
OFF
IUIa Wet
D
OFF
OFF
OFF
ON
IUUa Fullriver AGM
ON
ON
IUIa Discover AGM
Figure 4.1
13
ENGLISH
SKETCHES

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

50000582

Table of Contents