EMF Exposure

The effect of EMF exposure on humans and animals is a modern day concern. At the time of this
writing, to the best of our knowledge, no standards or recommendations exist regarding limits of
EMF exposure. Until evidence suggests that there is not a health risk associated with EMF
exposure, common sense would dictate that a practice of minimal exposure be exercised.

Battery Replacement

When the low battery message "LO BAT" appears on the left corner of the LCD, the 9V battery has
fallen to a critically low voltage level and should be replaced as soon as possible. The battery
compartment cover is located at the bottom rear of the meter. Slide off the battery compartment
cover, change the battery, and replace the compartment cover.
You, as the end user, are legally bound (Battery ordinance) to return all used batteries and
accumulators; disposal in the household garbage is prohibited!
You can hand over your used batteries / accumulators at collection points in your community
or wherever batteries / accumulators are sold!
Disposal: Follow the valid legal stipulations in respect of the disposal of the device at the
end of its lifecycle

Specifications

Display
Measurement rate
Maximum ranges and
resolution
Accuracy
Frequency bandwidth
Over-range indication
Operating
Temperature/Humidity
Power source
Power consumption
Dimensions
Weight
Copyright © 2012 Extech Instruments Corporation (a FLIR company)
All rights reserved including the right of reproduction in whole or in part in any form.
13mm (0.5") 3-1/2 digit (1999 count) LCD
with low battery and overload indication
Approx. 0.4 seconds
19.99µTesla (0.01) and 199.9mGauss (0.1)
NOTE: 1 µTesla = 10 milli-Gauss
± (4% + 3 digits) @ 50/60Hz
30 to 300Hz (single axis measurements only)
"1___" is displayed
Temperature: 0 to 50 C (32 to 122
RH: 90% max. (0 to 35 C); 80% max. (35 to 50 C)
9V Battery
Approx. 3mA DC
131 x 70 x 25mm (5.2 x 2.8 x 1")
165g (0.36 lbs.)
www.extech.com
3
o
F)